background image

INSTRUCTION MANUAL 

 

DIGITAL MULTIMETER 

 

KEW1020R 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

  

 

1. Safety Warnings 

 

This instrument has been designed, manufactured and tested 

according to IEC 61010: Safety requirements for electrical equipment, 

and delivered in the best condition after passing quality control tests. 

This instruction manual contains warnings and safety rules which have 

to be observed by the user to ensure safe operation of the instrument 

and to maintain it in safe condition. Therefore, read through these 

operating instructions before using the instrument. 

 

WARNING 

 Read through and understand the instructions contained in this 

manual before using the instrument. 

 Keep the manual at hand to enable quick reference whenever 

necessary. 

 The instrument is to be used only in its intended applications. 

 Understand and follow all the safety instructions contained in the 

manual. 

 It is essential that the above instructions are adhered to. Failure 

to follow the above instructions may impair the protection 

provided by the instrument and test leads, and may cause injury, 

instrument damage and/or damage to equipment under test.

 

 

The symbol    indicated on the instrument means that the user 

must refer to the related parts in the manual for safe operation of the 

instrument. It is essential to read the instructions wherever the 

symbol    appears in the manual. 

 

DANGER is reserved for conditions and actions that   

are likely to cause serious or fatal injury. 

WARNING is reserved for conditions and actions that   

can cause serious or fatal injury. 

CAUTION is reserved for conditions and actions that   

can cause injury or instrument damage. 

 

 Symbols listed below are used on this instrument. 

 

User must refer to the manual. 

        

 

Instrument with double or reinforced insulation. 

 

  

 

AC        DC        Ground (Earth) 

 

This instrument complies to WEEE Directive (2002/96/EC). 

Please contact your local distributor at disposal. 

  

Measurement Category 

O

 

Circuits which are not directly connected to the mains power supply. 

 

CAT II

 

Primary electrical circuits of equipment connected to an AC 

electrical outlet by a power cord. 

 

CAT III

 

Primary electrical circuits of the equipment connected directly 

to the distribution panel, and feeders from the distribution 

panel to outlets. 

 

CAT IV

 

The circuit from the service drop to the service entrance, and   

to the power meter and primary over current protection   

device(distribution panel).

 

 

This instrument is designed for CAT IV 300V/ CAT III 600V / CAT II 

1000V. Test leads M-7066A with the supplied caps are designed 

for CAT IV600V/ CAT III 1000V and without the caps are for CAT II 

1000V. 

  

  

  

  

  

 

DANGER 

 Never make measurements under the circumstances exceeding the 

designed measurement category and the rated voltage of the 

instrument. 

 Do not attempt to make measurement in the presence of flammable 

gasses. Otherwise, the use of the instrument may cause sparking, 

which can lead to an explosion. 

 Never attempt to use the instrument if its surface or your hand is wet.

 Do not exceed the maximum allowable input of any measuring 

range. 

 Never open the Battery compartment cover during a measurement. 

 To avoid electrical shock by touching the equipment under test or its 

surroundings, be sure to wear insulated protective gear. 

 Test leads to be used for voltage measurements shall be rated as 

appropriate for Measurement Category III or IV according to IEC 

61010-031 and shall have a voltage rating of 1000V or higher. 

 Barriers on the test leads provide protection to keep your fingers and 

hands from touching an object under test. Keep your fingers and 

hands behind the barriers during measurement. 

WARNING 

 Never attempt to make measurement if any abnormal conditions, 

such as broken case and exposed metal parts are found on the 

instrument or test leads. 

 Verify proper operation on a known source before use or take action 

as a result of the indication of the instrument. 

 

Firmly attach the caps to the test leads when performing 

measurements in CAT III or higher test environments. When 

KEW1020R and the test leads are combined and used together, 

whichever is lower category & voltage to earth either of them 

belong to is applied. 

 Do not rotate the Function Switch if the instrument and the   

equipment under test are connected. 

 Do not install substitute parts or make any modification to the   

instrument. For repair or re-calibration, return the instrument to your 

local KYORITSU distributor. 

CAUTION

 Use of this instrument is limited to domestic, commercial and light 

industry applications. Strong electromagnetic interference or strong 

magnetic fields, generated by large currents, may cause malfunction 

of the instrument. 

 Firmly insert the test leads. 

 Do not pull or twist the test leads to prevent the risk of damage. 

 Power off the instrument after use. Remove the battery if the 

instrument is to be stored and will not be in use for a long period. 

 Do not expose the instrument to direct sunlight, high temperature 

and humidity or dewfall. 

 Use a cloth dipped in water or neutral detergent for cleaning the 

instrument. Do not use abrasives or solvents. 

NOTE

 The LCD shows some digits at the Voltage range even while the test 

leads are open. And, it may show some digits instead of 0 even if the 

test leads are shorted. However, these phenomena don’t affect 

measurement results. 

 A resistance measurement takes time to settle the reading if there is 

a high resistance or capacitance components.

 

 

2. Specification

 

   

 Accuracy (Temperature: 23 ± 5°C, Humidity: 45 - 75%) 

 

 

ACV

  / 

RMS

                    

 

               

(Auto Range)

 

Range

Display Range

Accuracy (sine wave)

6V

0.000, 0.006 - 6.299V

±1.0 %rdg±3dgt (40-500Hz) 

60V

5.70 - 62.99V

600V

57.0 - 629.9V

1000V

570 – 1049V

±1.3 %rdg±3dgt

(40-500Hz)

Guaranteed accuracy : 0.01V-1000V,    less than 1500V peak 

Input impedance : approx. 10M

 

Input protective voltage : AC/DC1200V 10 sec. 

 

Hz  Frequency - 

ACV measurement

     

     

 

(Auto Range)

 

Range 

Display Range 

Accuracy 

(sine wave) 

99.99Hz

10.00 - 99.99Hz

±0.1%rdg±3dgt 

999.9Hz

95.0 - 999.9Hz

9.999kHz

0.950 - 9.999kHz

99.99kHz

9.50 - 99.99kHz

Guaranteed accuracy : 10Hz-99kHz 

Input protective voltage : AC/DC1200V 10 sec. 

 

%    DUTY - 

ACV measurement

 

Range 

Display Range 

Accuracy 

(Square wave) 

99.9 % 

0.0 – 99.9 % 

±1.0%rdg±3dgt (50/60Hz) 

Guaranteed accuracy : 10%-90% 

Input protective voltage : AC/DC1200V 10 sec. 

 

DCV

      

 

 

           

 

 

           

(Auto Range)

 

Range

Display Range

Accuracy

6.000V

0.000 - ±6.299V

±0.5 %rdg±3dgt 

60.00V

±5.70 - ±62.99V

600.0V

±57.0 - ±629.9V

1000V

±570 - ±1049V

±0.8 %rdg±3dgt

Guaranteed accuracy : 0V-±1000V 

Input impedance : approx. 11M

(6V range) / 10M

(60/600/1000V range) 

Input protective voltage : AC/DC1200V 10 sec 

 

 

ACmV  / RMS 

Range

Display Range

Accuracy (sine wave)

600.0mV 

0.0, 0.9 - 629.9mV 

±2.0 %rdg±3dgt (40-500Hz) 

Guaranteed accuracy : 1.2mV-600mV,    less than 900mV peak 

Input impedance : approx. 900k

 

Input protective voltage : AC/DC1000V 10 sec. 

 

AC Clamp Sensor    / RMS 

  

 

            

  (Auto Range)

 

Range

Display Range

Accuracy (sine wave)

60.00A

0.00, 0.09 - 62.99A

±2.0 %rdg±3dgt 

  + Sensor accuracy (40-500Hz)

200.0A

57.0 - 209.9A

Direct reading from 10mV / A output Clamp sensor 

Guaranteed accuracy : 0.12A-200A,    less than 300A peak 

Input impedance : approx. 900k

 

 

 

 

 

DCmV 

Range

Display Range

Accuracy 

600.0mV

0.0 - ±629.9mV

±1.5 %rdg±3dgt 

Guaranteed accuracy : 0mV-±600mV,    Input impedance : approx. 900k

 

Input protective voltage : AC/DC1000V 10 sec. 

 

DC Clamp Sensor 

    

 

   

  

 

                 

  (Auto Range) 

Range

Display Range

Accuracy 

60.00A

0.00 - ±62.99A

±1.5 %rdg±3dgt 

+

 

Sensor accuracy 

200.0A 

±57.0 - ±209.9A 

Direct reading from 10mV / A output Clamp sensor

 

Guaranteed accuracy : 0A-±200A,    Input impedance : approx. 900k

 

 

Resistance

 

 

 

       

         

 

  

   

(Auto Range) 

Range

Display Range

Accuracy 

600.0

0.0 - 629.9

±0.5 %rdg±4dgt 

6.000k

 

0.570 - 6.299k

 

±0.5 %rdg±2dgt 

60.00k

5.70 - 62.99k

600.0k

57.0 - 629.9k

6.000M

0.570 - 6.299M

40.00M

5.70 - 41.99M

±1.5 %rdg±3dgt 

Guaranteed accuracy : 0

-40M

,    Open-loop Voltage : less than 3V 

Measurement current : less than 1mA 

Input protective voltage : AC/DC1000V 10 sec.

 

 

Continuity 

Range

Display Range

Accuracy 

600.0

 

0.0 - 629.9

 

Buzzer threshold value : 

less than 90

 

Open-loop Voltage : less than 3V, Measurement current : less than 1mA 

Input protective voltage : AC/DC1000V 10 sec.

 

 

Diode 

Range

Display Range

Accuracy 

2.000V 

0.000 - 2.099V 

±5 %rdg±5dgt 

Guaranteed accuracy : 0V-2V,    Open-loop Voltage : less than 3V 

Measurement current : approx.0.5mA (Vf=0.6V) 

Input protective voltage : AC/DC1000V 10 sec.

 

 

Capacitance

 

  

                       

  (Auto Range) 

Range

Display Range

Accuracy 

60.00nF

0.00 - 62.99nF

±2.0 %rdg±5dgt* 

600.0nF

57.0 - 629.9nF

6.000µF

0.570 - 6.299µF

±5.0 %rdg±5dgt 

60.00µF

5.70 - 62.99µF

600.0µF

57.0 - 629.9µF

1000µF

570 - 1049µF

* Accuracy after canceling floating capacitance using REL function. 

Guaranteed accuracy : 0nF-1000µF 

Input protective voltage : AC/DC1000V 10 sec.

 

 

 

Measuring method : 

Σ

 modulation 

Over-range indication : OL 

Measurement cycle : 2.5 times per second 

(1000µF range of Capacitance function 0.05 times per second) 

Crest factor : less than 3 (45-65Hz) 

For non-sinusoidal waveforms, add ±0.5 %rdg±5dgt 

(Applicable functions : ACV, ACmV, AC clamp sensor) 

Applicable standards : 

IEC 61010-1 /61010-2-033 :   

CAT IV 300V / CAT III 600V / CAT II 1000V 

Pollution degree 2, Indoor use, Altitude up to 2000m 

IEC61010-031 (Test leads Model 7066A) 

IEC 61326 (EMC) , EN 50581 (RoHS) 

Withstand voltage : AC5160Vrms 5sec between circuit and enclosure 

IP rating : IP40 (IEC60529) 

Insulation resistance : 100M

 or more /1000V between enclosure   

and electrical circuit 

Operating temperature and humidity range : 

0 to

 

40°C, 80%RH or less (no condensation) 

Storage Temperature and humidity range : 

-20 to 60°C, 80%RH or less (no condensation) 

Power source : DC3V R03/LR03 (AAA) × 2 

Current consumption : 3mA or less 

Battery life : Approx. 200 hours (ACV, continuous, no load, with R03) 

Dimension, Weight : 155(L)×75(W)×40(D)mm,   

approx. 250g (including batteries and Wing-type holder) 

Accessories : Test leads (M-7066A), Instruction manual,   

Battery R03 (AAA) 2pcs, Wing-type holder 

Option : Magnet hanger strap (M-9189) 

Test leads with alligator clips (M-7234) 

AC Clamp Sensor (KEW8161), AC/DC Clamp Sensor (KEW8115) 

Function Switch 

Cap Barrier 

REL / MAX

MIN Key 

SELECT Key 

Voltage Terminal 

COM Terminal 

HOLD / Backlight Key 

LCD 

3. ACV / DCV / ACmV / DCmV Measurement 

  

DANGER

 

 Before starting a measurement, always check and confirm 

the Function switch is in the appropriate measurement 

position. 

 Never make measurement on a circuit in which voltage over 

1000V exists. 

 Keep your fingers and hands behind the barrier during   

measurement.

 

  

3.1 ACV / DCV/ ACmV / DCmV measurement 

 

(1) Set the Function switch to ACV, DCV, ACmV or DCmV position.   

For frequency or DUTY measurement, set the switch to ACV   

and press the SELECT key. 

 

 
 
 
 
 
 
 

  

(2) Connect the test leads to the Voltage and COM terminals. 

 
 
 
 
 
 
 
 

 

 

3.2 Clamp sensor (option) measurement 

  

(1) Set the Function switch to ACmV or DCmV position and press the 

SELECT key. LCD shows “SENSOR”. 

 

 
 
 
 
 
 
 

 

 

 

(2) Connect the clamp sensor to the Voltage and COM terminals. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE 

 If the connection is reversed, the “ 

  “ mark will be displayed on the 

LCD. (DCV measurement). 

 Press the REL key to adjust the reading on the DC clamp sensor to 

“0”. 

 

The sensor mode corresponds to direct reading with 10mV/A 

output clamp sensor.   

 

 

 

 

 

4. Resistance / Diode / Continuity / Capacitance   

Measurement 

  

WARNING

Never use the instrument on an energized circuit. Discharge the 

capacitor before starting a capacitance measurement. 

  

(1) Set the Function switch to the resistance, continuity or capacitance   

position. For diode measurement, press the SELECT key. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

(2) Connect the test leads to the Voltage and COM terminals. 

 

 
 
 
 
 

 

 

 
 
 
 

NOTE 

 LCD shows ”OL” when the test leads are open. 

(except for capacitance measurement) 

 The LCD shows “OL” if the test lead connection is reversed for diode 

measurement. 

 Measurement time on 600

μ

F/1000

μ

F range is a bit long. 

(20sec max.) 

 

  

5. Other Functions 

  

 REL Function 

Press the REL key to enable this function and store the measured 

value to display the differences between the stored value and the 
values measured in further tests. The measurement range will be 

fixed when the REL function is enabled, and the measuring range will 

be between the initial value and the full scale value. 

Press the REL Key again to release the stored value. 

 

 

 

 
 

 

 

*To activate REL function, MAX/MIN function should be disabled. 

  

 Sleep Function

 

Automatically powers off the instrument in about 15 min after the last 

switch operation. 

 

To exit from the Sleep mode, rotate the Function switch or press any   

key. To disable the Sleep function, press the HOLD/Backlight key   

and power on the instrument. 
Confirm that the LCD shows “P.OFF” about 1 sec. 

 

 Max / Min value display function 

    This function is to display the measured max and min values on the 

LCD during a measurement. Press the MAX/MIN key 1 sec or longer 

to start recoding of max and min values. Then the LCD shows the 

latest max value. After that, the min and present values can be 
toggled and checked by pressing the MAX/MIN key (less than 1 

sec).

 

To disable this function, press the MAX/MIN key 1 sec or longer.

 

 

 
 
 
 
 
 
 
 

 

 

* To activate MAX/MIN function, REL function should be disabled. 

 

 Data hold function 

Press the HOLD key (less than 1 sec). The LCD shows “H” mark and 

the reading will be held (Data hold mode). The max/ min values are 

not updated in MAX/MIN mode. Press the HOLD key   
again (less than 1 sec) to release the display. 

 

 Backlight function 

  

Press the Backlight key 1 sec or longer to turn   

on the backlight. Press the Backlight key another 1 sec or longer to   

turn it off. The light automatically turns off in 1 min. 

 

 Low battery indication 

The LCD shows “            ” mark when the batteries fall below the   
normal operating voltage. 

 

 
 

 
 

How to store test leads 

Attach the Wing-type holder to the back of the instrument to store the 

test leads. 

1. Attach the Wing-type holder to the back of the instrument. 

2. Fit the barrier on the test lead into the groove between the   

instrument and the Wing-type holder. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Then it will be easier to see the displayed readings during a   

measurement. 

 

 Other convenient functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Battery Replacement 

 

WARNING 

 Replace the battery when the "            " mark- low battery voltage   

warning- appears on the LCD.   
Otherwise, precise measurement cannot be made. If the battery   

is completely exhausted, the LCD goes blank without showing   

the "      " mark. 

 Disconnect the test leads from the object under test and power 

off the instrument before opening the Battery compartment 

cover for battery replacement. 

 Do not try to replace the battery if the surface of the instrument 

is wet.

 

CAUTION

 

 Do not mix old and new batteries. Brand and type of the 

batteries to be used should be harmonized. 

 Install a batteries in correct polarity as indicated in the   

  Battery Compartment. 

 

(1) Set the Function Switch to "OFF" position. 
(2) Untighten the screw on the back of the instrument. 

(3) Remove the Battery compartment cover and replace the   

batterie.  

(4) Attach the cover to the instrument and then secure the cover   

by tightening the screw. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

11-15 92-2256 

Press the SELECT key to toggle functions 

Resistance

  or Capacitance 

Diode

Screw 

Battery 

AC clamp sensor 

DC clamp sensor 

Black 

Red 

Press the SELECT key to toggle functions

Black

Red

Continuity 

Default : ACV 

Frequency 

DUTY 

Kyoritsu reserves the rights to change specifications or designs 

described in this manual without notice and without obligations. 

Black 

Red 

ACV / ACmV 

DCV / DCmV 

Default :ACmV 

Sensor mode 

(ACA) 

Default :DCmV 

Sensor mode 

(DCA) 

Press the SELECT key to toggle functions 

Magnet hanger strap 

(option) 

” appears and “AUTO” disappears 

  when REL Key is pressed. 

One press: REL ON 

Another press: REL OFF 

Max value

 

Min value

Present value

Less than 1 sec

Less than 1 sec

Less than 1 sec

1.

2.

Wing-type

holder 

3.

Replace the batteries   

with new ones when this 
mark appears. 

Tilt stand 

Default : Continuity 

Diode

 

Resistance

Capacitance

Continuity / Diode 

Reviews: