― 7 ―
Range
200mA
2A
20A
200A
1000A
Measuring Range
0〜200mA
0〜2A
0〜20A
0〜200A
0〜500A
501A〜1000A
AC Output Voltage
Accuracy
0〜200mV
±2.0%rdg±0.5mV
±2.5%rdg±0.5mV
±3.0%rdg±0.5mV
±5.0%rdg±0.5mV
0〜50mV
50〜100mV
Analogue Output (Output impedance: Approx. 1kΩ)
●AC Output
*Voltage proportional to the current under test is output with
WIDE
frequency characteristics regardless of the setting of the
frequency Selector or peak hold switch.
●DC Output
*DC voltage is output in proportion to the display reading, which
reflects frequency selector or peak hold switch position
−
200mV
DC for 2000 count reading.
200mA
2A
20A
200A
1000A
0〜200mA
0〜2A
0〜20A
0〜200A
0〜500A
501A〜1000A
Ranges
AC Input
Current
DC Output
Voltage
Accuracy (Frequency Range)
Freq. Selector
Switch at
WIDE position
Freq. Selector
Switch at 50/60Hz
position
0〜200mV
±3.0%rdg±0.5mV
±3.5%rdg±0.5mV
±5.0%rdg±0.5mV
±7.0%rdg±0.5mV
±3.5%rdg±0.5mV
±4.0%rdg±0.5mV
±5.5%rdg±0.5mV
±7.5%rdg±0.5mV
0〜50mV
50〜100mV
Summary of Contents for KEW SNAP 2413R