2HA/2HB
1-5-24
(2) Detaching and refitting the drum separation claws
Follow the procedure below to replace the drum separation claws.
Procedure
1. Remove the drum unit (see page 1-5-23).
2. Push the drum separation claws with the
minus driver from the top of the corner
hole and remove the claws.
3. Replace the drum separation claws and
refit all the removed parts.
Figure 1-5-53
Drum unit
Drum separation claws
Drum
separation
claw
Coner hole