Mounting
10
Caution:
As part of the heat dissipation system, the switch housing becomes hot during operation.
Please use caution when coming in contact and avoid covering the switch housing when the
switch is running.
The figures in this manual are only for reference.
3.2 Mounting Modes and Steps
The series devices support panel mounting. Before installation, make sure that the following
requirements are met.
1) Environment: temperature (-40
℃
to 70
℃
), ambient relative humidity (5% to 95%,
non-condensing).
2) Power requirement: The power input is within the voltage range of the switch.
3) Grounding resistance: <5
4) No direct sunlight, distant from heat source and areas with strong electromagnetic
interference.
5) Devices are to be installed in an authority certified enclosure and accessible only by the
use of a tool.
6) Devices should be installed and accessed by service personnel or users who have been
instructed about the reasons for the restrictions applied to the location and about any
precautions that shall be taken.
Mounting
Step 1: Select the mounting position (on a wall or inner wall of a cabinet) for the device and
guarantee adequate space and heat dissipation.
Step 2: Punch four holes in the selected position according to the dimensions of the device.
Put the screw holes of device in alignment with the corresponding punched holes.
Then use four screws to secure the device to the wall or inner wall of a cabinet.