Figure 2 Dimensions(unit: mm)
7
31.8 44
11
185
483
465.4
440
3
3.1 Dimension Drawing
3 Mounting
3.2 Mounting Modes and Steps
The series devices support rack mounting by front panel. Before installation,
make sure that the following requirements are met.
1) Environment: temperature (-40
℃
to 75
℃
), ambient relative humidity (5% to
95%, non-condensing).
2) Power requirement: The power input is within the voltage range of the switch.
3) Grounding resistance: <5
Ω
4) No direct sunlight, distant from heat source and areas with strong electro
magnetic interference.
5) Devices are to be installed in an authority certified enclosure and accessible
only by the use of a tool.
6) Devices should be installed and accessed by service personnel or users
who have been instructed about the reasons for the restrictions applied to the
location and about any precautions that shall be taken.
●
As part of the heat dissipation system, the switch housing becomes
hot during operation. Please use caution when coming in contact and
avoid covering the switch housing when the switch is running.
●
The figures in this manual are only for reference.
Caution: