Kyland Telecom
-25-
Count er sunk
Fl at head
Scr ews
W
al l
Hangi ng
Pl at e
Figure 4-4 Mounting wall-mounting plate
3
.
Select mounting position: vertical wall or inner wall of cabinet. If you select to
mount on vertical wall, you are recommended to use
Ф
6 plastic expansion bolts
and
Ф
3 tapping screws for equipment mounting. According to the mounting
dimensions marked in Figure 4-3, drill four
Ф
6 holes with an impact drill on the
wall (the depth of the holes should allow fully inserting the plastic expansion
bolt), fully insert the plastic expansion bolts in the holes on the wall, screw down
the tapping screws into the plastic expansion bolts with a cross head screwdriver
but do not screw down thoroughly, reserve a distance of around 5
㎜
; if you select
to mount on the inner wall of cabinet, you are recommended to prepare four M3
threaded holes on the inner wall of cabinet when making the cabinet according to
the mounting dimensions marked in Figure 4-3, or drill four
Ф
4 holes with a
hand-held electric drill on site, and screw down four M3
×
10 pan head screws
with cross recess into the four holes with a cross head screwdriver (if the holes
are not threaded inside, it is necessary to mount four M3 nuts on the back side).
Do not screw down the screws thoroughly, reserve a distance of around 5
㎜
.