KYL KYL-500L Quick Start Manual Download Page 5

Shenzhen KYL Communication Equipment Co., Ltd

Fax: +86-755-83408785        [email protected]               www.rf-data.com

5

4. Setting of channel, interface, and data format

Before using KYL-500L, the user needs to make simple configuration according
your own  needs  to  determine  the  channel, interface  mode  and  data format. You
can  view  or change  the  module's  interface  baud rate, channel  and  address  code. 
Please  read  or  set  the  parameters as  per  the  testing  software  KYLCOM.exe (in 
products box). And the configuration is as follows:

i. Channel configuration:

Channel No.

Frequency

Channel No.

Frequency

1

429.0325MHZ

5

433.0325MHZ

2

430.0325MHZ

6

434.0325MHZ

3

431.0325MHZ

7

435.0325MHZ

4

432.0325MHZ

8

436.0325MHZ

Note:  the  frequency  points  corresponding  to  each  channel  can be  adjusted 

based on user’s needs.

5. 

Installation dimension (mm):

                               

Summary of Contents for KYL-500L

Page 1: ...Terminal Shenzhen KYL Communication Equipment Co Ltd Address C3705 3707 Huangdu Square South of Exhibition Center Yitian Road Futian District Shenzhen Guangdong China 518048 Tel 86 755 82943662 Fax 86...

Page 2: ...transmission distance is 2km 1200bps and is 1 5km 9600bps respectively 5 Transparent data transmission Transparent data interface used in transceivers is to meet many standard and nonstandard user pr...

Page 3: ...ss data transmission automatic data collection system Radio modem can be used for Sports training competition Electronic bus station and intelligent traffic Wireless electronic display screen and queu...

Page 4: ...unicipal electric supply 2 Connection Definition with terminal KYL 500L transceivers provide one 9 pin connector JP1 their definitions and connection methods with terminals are shown in Table 1 Table...

Page 5: ...an view or change the module s interface baud rate channel and address code Please read or set the parameters as per the testing software KYLCOM exe in products box And the configuration is as follows...

Page 6: ...struction In order to reduce more consumption KYL 500L transceivers support Sleep function In sleep mode the current consumption is less than 1uA a How to use the Sleep function The Pin8 SLP in JP1 is...

Page 7: ...ivers between the first bit sent by TxD to the first bit received by RxD As data processing happens on user s data by KYL 500L transceiver using FEC Forward Error Correction or other correction algori...

Page 8: ...uipment ARQ Reasons If the actual transmission BER Bit Error Rate is 10 4 1 packet with 1KB data which is about 10 thousand bits is sent theoretically at least 1 bit will be received wrongly So the 1K...

Page 9: ...website http www rf data com Products_list_en asp classid 163 If you have special demands on antennas please specify we can design and produce for you individually V Network Application of KYL 500L Th...

Page 10: ...he programming of serial port all you have to do is to remember that its communication mode is semi duplex while always observing the time sequence of come and go for receiving and transmitting VI Tec...

Reviews: