will be deserted without any response. If those address codes are the same, it
means the data is sent to the local. Slave station will make different responses
according to the transmitted data or command and send back the data of response.
All these jobs must be performed by upper protocol, and it is assured that there is
only one transmitter-receiver in the state of transmission in the communication
network at any instant moment so as to avoid the cross-interference.
KYL-300L can also be used for point-to-point communication with easier
operation. For the programming of serial port, all you have to do is to remember
that its communication mode is semi duplex while always observing the time
sequence of come-and-go for receiving and transmitting.
VI. Technical specification of KYL-300L
* Modulation mode: GFSK/FSK
* Working frequency: 400MHz~470MHz, 868MHz, 915MHz;
* Power supply: DC 5V (7.5V~12V informed when placing the order);
* RF power:
≤
500mW, 600mW~1W is available;
* RF data rate: 1200/2400/4800/9600/19200bps (Set before delivery);
* Receive current: <28mA (TTL connect);
* Receive sensitivity: -123dBm (1200bps); -118dBm (9600bps);
* Transmitting current: <350mA;
* Sleep current: <20uA;
* Interface port: RS232/RS485/TTL/USB
* Interface data format: 8E1/8N1/8O1;
* Working humidity: 10%~90% relative humidity without condensation;
* Working temperature: -35
~+75( industrial)
* RF Line-of-sight Range: 2000m(BER=10-5@9600bps);
3000m(BER=10-5@1200bps)
;
* Size: 80mm*45mm*19mm (without antenna port).