![KYL KYL-300I Quick Start Manual Download Page 5](http://html1.mh-extra.com/html/kyl/kyl-300i/kyl-300i_quick-start-manual_2014768005.webp)
Shenzhen KYL Communication Equipment Co., Ltd
Fax: +86-755-83408785
www.rf-data.com
5
4. Setting of channel, interface, and data format
Before using KYL-300I, you need to make simple configuration on your own
needs to determine the channel, interface mode and data format. You can view or
change the module's interface baud rate, channel and address code. Please read or
set the parameters as per the testing software KYLCOM.exe (in products box).
And the configuration is as follows:
i. Channel configuration:
Channel No.
Frequency
Channel No.
Frequency
1
429.0325MHZ
5
433.0325MHZ
2
430.0325MHZ
6
434.0325MHZ
3
431.0325MHZ
7
435.0325MHZ
4
432.0325MHZ
8
436.0325MHZ
Note: the frequency points corresponding to each channel can be adjusted
based on the user’s needs.
5
.
Installation dimension: