How to instal-Separation cool and hot water type

How to install - Under sink water supply system/General model type

Installation

Under sink installation

Nipple with a hole

Nipple with a hole

Switch valve of incoming water 
(Controlling the water pressure)

c

‘O’ Shape Packing

‘O’ Shape Packing

Switch valve of incoming raw water

The connecting hose with product 

for incoming water

General model type installation

Nipple with a hole

Switch valve of incoming water

Hose stop down nut

‘O’ Shape Packing

‘O’ Shape Packing

The connecting hose with 
product for incoming water

If you mix up the raw water inlet with the acidic water outlet, alkali water will not be produced 

and be the cause of a failure. So you must not install reversely between the raw water inlet and

the acidic water outlet. If the failure happens because of a reverse installation, the man who 

installs the product will have to be charged with the failure.

Cut the acidic water draining hose about 50cm~70cm and connect with the acidic water outlet 

(after removing the rubber stopper) as the same connecting way at the raw water inlet in 11 page.

You have to cut the acidic water draining hose within 1m because if the length is over 1 m, 

we will be possible to smell in the water.

The acidic water draining hose is placed lower than the body not to affect the quality of water.

Connect and assemble the alkali water delivery pipe (flexible hose) by turning to clockwise 

direction with the alkali water outlet placed on the upper side of the body. 

(When the leakage is happened, reassemble the product after wrapping up the tape properly.)

Before operating the product, check the leakage by opening the switch valve and there is 

no problem then operate the system.

How to check the water pressure and set up

1)

When you use a measuring instrument: Measure the pressure of raw water with a measuring

instrument and if the water pressure is low then you will increase the pressure of raw water 

and if the incoming water pressure to the product is low then, you will increase the pressure 

by using the water pressure controlling valve (see the installation figure). 

(Standard -Adjust over 2.0

/min.)

2) When you do not have a measuring instrument (A simple measuring way)

: If water can be filled in the vending machine cup during 6~7 seconds, the water pressure is 

about 1.8

/min and it is the proper water pressure for operating the product

Summary of Contents for KYK Generation II

Page 1: ...440 Sangdaewon Dong Joongwon Gu Sungnam City Kyunggi Do KOREA zipcode 462 120 82 31 777 3939 FAX 82 31 777 3456 COMMON USE MANUAL KYK Co Ltd promises to treat every customer fairly and respectfully w...

Page 2: ...convenience and an improvement of product you will contact us at any time Again we sincerely value you as our customer and hope that this will be the beginning of a satisfying relationship Thank you S...

Page 3: ...al due to the wide range of tap water quality in North America Non programmable ionizers cannot adjust to local tap water conditions so these ionizers are at the mercy of your tap water and a handful...

Page 4: ...ents Stainless Steel Water Output Hose Output for alkaline acidic or purified water as selected by user LCD Display Displays pH ORP remaining filter life both filters error messages and water flow rat...

Page 5: ...on in Liters Minute Voice Voice prompt on off Voice level pH Level pH level display toggled between pH using SET Touch Sensor Filter 1 Filter life remaining for 1st filter in liters Filter 2 Filter li...

Page 6: ...ch sensor to increase or decrease the pH level alkalinity of water to be produced The pH level or the ORP value of the water being produced will be displayed on the LCD display Touch the Set touch sen...

Page 7: ...6 setting the pH level of the incoming water step 8 and maximizing the ORP value step 14 You may also consider performing step 12 You must start at step 1 You can exit programming at any time by touch...

Page 8: ...tioxidant capabilities more ability to counter free radical activity in the body It is recommended that you do this Hold the touch sensor down to obtain the highest negative ORP value and then touch t...

Page 9: ...order it separately We accept a request in the A S center Warning You wrap the tape for preventing the leakage 4 5 times not to harm on the connection between nipple and piping and after complete con...

Page 10: ...inlet in 11 page You have to cut the acidic water draining hose within 1m because if the length is over 1 m we will be possible to smell in the water The acidic water draining hose is placed lower th...

Page 11: ...tallation Troubleshooting 1 If there is no water flow Check to make sure you removed the rubber stoppers on the inlet and outlet valves Check the faucet or under sink adapter to make sure that the val...

Page 12: ...ced in the sink The product power cord is plugged into an above the counter electrical outlet Ionized water is delivered via the ionized water output hose on top of the product The information on page...

Page 13: ...ure the tubing is pressed all the way into the connector IMPORTANT Note To remove tubing from a quick connect connector push the ring on the connector in towards the body of the product and gently pul...

Page 14: ...27 Plug the Genesis power cord into a AC120V American type and AC 220V 240V European type electrical outlet 28 Adjust the input water pressure water flow rate into the product using the faucet You wan...

Page 15: ...e steel flex hose onto the male threads of the diverter valve Tighten securely Feed the 1 4 tubing connected to the IN quick connect connector on the bottom of the product down through the access hole...

Page 16: ...s First rinse rick in pH 8 5 alkaline water and then cook that rice in pH 10 0 water to quicken cooking time reduce damage to the rice and maintain it natural flavor Remove spots and stains Reduce det...

Page 17: ...nt part 4 Hold the filter and turn it to the right OPEN then pull out The old filter can now be taken out of the product 5 Please remove the safety seal of the new filter Insert the new filter bottom...

Page 18: ...t off drinking the 1ss alkaline water level 8 5 pH and drink 2 3 glasses a day for 1 week then drink 2 3 glasses a day of the 2nd level alkaline water 9 0 pH for the second week Typically most adults...

Page 19: ...etector Over Temperature Protector Electr olysis Filter OutputCapacity Electrolysis Ability Electrolysis Cell Electrode Sheet Wash Filter Life Estimate Message to indicate Filter Change Filtering Mate...

Page 20: ...age 5 Damage is caused by using an imitation filter 6 Damage is caused by a natural disaster 7 Damage is caused by exposing the electronics to water or moisture Terms of Warranty one years parts and l...