![background image](http://html1.mh-extra.com/html/kye-systems-corp/genius-sw-j2-1-500/genius-sw-j2-1-500_service-manual_2014734007.webp)
Service Guide
SW-J2.1 500
*Attention
Please follow the numbered sequence marked within parenthesis given in
individual
Flow chat in that this is the best-recommended sequence to rectify the problems.
1.2.1 No power
,
LED
(
indicator
)
unlighted
Problem
Analyze
and
identify
the
causes
Solutions
Version 1.0 Page 7 of 23
No power
,
LED
(
indicator
)
unlighted
Repair or replace
Defective transformer
Defective or damaged
AC cable or power
switch
resolder or replace
Or caused by the following:
1. Transformer secondary wire loosely connected with PT1
jack in
J2.1 500 AMP
.
2. Copper foil of
J2.1 500 AMP
PCB broken