Service Guide
iTempo 350
Version : 1.0
Page 8 of 15
1.2.2
Power LED (indicator) no light
Problem
Solutions
1.2.3 Volume no function
Problem
Solutions
Power LED (indicator) no light
Power switch or LED defective
DefectiveU2,U3,U5,U
6,R19,R28,C10,Y1.
DC Adaptor
disconnected or defective
Re-solder or replace
defective component(s)
Analyzer and
Identify the Causes
Volume no function
Broken or short circuit
DefectiveU5,U6,U7,U8,C54
,C55,JACK4,Q8,
Check solder points on PCB
Analyzer and
Identify the Causes
Check and Replace defective
components
Summary of Contents for Genius iTempo 350
Page 1: ...Service Guide iTempo 350 Version 1 0 Page 1 of 15 SERVICE GUIDE KYE SYSTEMS CORP iTempo 350...
Page 11: ...Service Guide iTempo 350 Version 1 0 Page 11 of 15 Chapter 4 Exploded View...
Page 13: ...Service Guide iTempo 350 Version 1 0 Page 13 of 15 Chapter 6 Schematic Diagram...