KYA N5023 Operating Manual Download Page 3

 

 

 

WARNING:  
 
The operating instructions shall draw attention to the following 

a) 

Only those fasteners listed in the operating instructions may be used in the fastener driving 

tools; 

NOTE:

 The fastener driving tool and the fasteners listed in the operating instructions must be 

seen as one unit system in terms of technical safety. 

b)

 Only the main energy and the lubricants listed in the operating instructions may be used; 

c)

 Fastener driving tools marked with an inverted equilateral triangle standing on one point 

may only be used with an effective safety yoke; 

d) 

Fastener driving tools equipped with contact actuation or continuous contact actuation, 

marked with the symbol “Do not use on scaffoldings, ladders”, shall not be used for specific 
application for example: 
when changing one driving location to another involves the use of scaffoldings, stairs, ladders, 
or ladder alike constructions, e.g. roof laths, closing boxes or crates, fitting transportation 
safety systems e.g. on vehicles and wagons; 

e)

 For the maintenance of fastener driving tools, only spare parts specified by the 

manufacturer or his authorized representative shall be used; 

f)

 Repairs shall be carried out only by agents authorized by the manufacturer or by other 

specialists, having due regard to the information given in the operating instructions; 

NOTE:

 Specialists are those who, as a result of professional training or experience, have 

sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant 
governmental industrial protection provisions, accident prevention regulations, directives and 
generally recognized technical regulations (e.g. CEN- and CENELEC-standards), to be able to 
assess the safe working condition of fastener driving tools. 

g)

 Stands for mounting the fastener driving tools to a support for example a work table, shall 

be designed and constructed by the stand manufacturer, in such a way that the fastener 
driving tool can be safely fixed for the intended use, thus for example avoiding damage, 
distortion or displacement. 

 

Additional instructions for fastener driving tools operated by compressed air 

a)

 Fastener driving tools operated by compressed air shall only be connected to compressed 

air lines where the maximum allowable pressure cannot be exceeded by a factor of more than 
10%, which can for example be achieved by a pressure reduction valve which includes a 
downstream safety valve; 

b)

 When using fastener driving tools operated by compressed air, particular attention must be 

paid to avoid exceeding the maximum allowable pressure; 

c) 

Fastener driving tools operated by compressed air should only be operated at the lowest 

pressure required for the work process at hand, in order to prevent unnecessarily high noise 
levels, increased wear and resulting failures; 

d)

 Hazards caused by fire and explosion when using oxygen or combustible gases for 

operating compressed air operated fastener driving tools. 

 
 
 

Summary of Contents for N5023

Page 1: ...derstand the instructions in this manual before operating the pneumatic power tool Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the Manual be...

Page 2: ...ilers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a potentially hazardous situation before it occurs and by observing appropr...

Page 3: ...ssional training or experience have sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant governmental industrial protection provisions accident preventi...

Page 4: ...els which can lead to hearing damage the employer and user should ensure that any necessary hearing protection is provided and used by the operator and others in the work area 3 DO NOT USE ANY POWER S...

Page 5: ...enever the air supply is connected to the tool never touch the trigger unless you intend to drive a fastener into the work It is dangerous to walk around carrying the tool with the trigger pulled and...

Page 6: ...may result Do not interfere with the proper operation of the contact trip mechanism 18 WHEN USING THE TOOL OUTSIDE OR ELEVATED PLACE When fastening roofs or similar slanted surface start fastening at...

Page 7: ...5 34lbs Actuation mode Contact actuation Magazine capacity 150 staples Maximum allowable pressure 120psi 8 3bar Recommended pressure range 70psi to 100psi 5bar to 7bar Fasteners Only the staple sizes...

Page 8: ...ly compressed air to this nailer Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The femal...

Page 9: ...ood are factors in determining what the pressure should be set at Do not exceed this recommended operating pressure NOTE Dirt and water in the air supply are major causes of wear in the tool An air fi...

Page 10: ...n to MAGAZINE 310970 end fix NAIL FEEDER 324710 on STRAIGHT PIN 324720 3 MAGAZINE COVER B 310840 is opened feed a strip staples into MAGAZINE 310970 slide it towards to NOSE 211470 then feed the secon...

Page 11: ...he nailer rail with nailer lubricant Clearing a jam Remove a jammed nail in the following order 1 DISCONNECT AIR HOSE 2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In c...

Page 12: ...47 2X2 45 65 420160 PIN CAP B 21 324700 WASHER 66 324300 NUT 22 410910 BUMPER 67 310880 COVER A 23 110580 BODY 68 640460 ROLL PIN 2X40 24 410140 HANDLE GRIP 69 211180 NOSE COVER A 25 520370 END CAP SE...

Page 13: ...TOOL SCHEMATIC N5023...