KwiKool Attic Master KAM Series Operation Manual Download Page 4

IV / Operating Procedure

A.

B.

On/Off Switch - 2-position switch, turns unit on or off.

Fan/Cool Switch - 2-position switch, turns unit fan only on or fan with compressor 
on.

Low/High Switch - 2-position switch, turns the fan from 

low

 speed for use with a 

30’ duct or 

high

 for use with a 60’/90’ duct.

The AtticMaster controls are located on the top right side on the front of the unit. 
There are 3 switches (See Unit Components):

Page 4

III / Quick Start Procedure

1.

2.

3.

A.

B.

Select Location of System 

- Make sure all sides of unit are not blocked to avoid 

restricted air flow.

Remove duct from bag

 - Attach duct clamp to the ring on top of the unit, making sure 

the clamp is tight and run eyelets into the ring.

Attaching extra 30’ length of duct

 - Squeeze duct end loop and insert into first duct 

end loop. A maximum of three 30’ lengths of duct can be used for a total maximum 
length of 90’. At least one 30’ length must be connected to the unit for proper back 
pressure.

Outlet 

- Only use a dedicated 115 Volt / 15 Amp circuit, such as the outlet for a 

washing machine.

C.

D.

Condensate tank with a float switch is located in the front lower compartment of the 
unit. When the tank is full a beeping alarm will sound. When removing the tank, 
unplug the float jack. When replacing the tank make sure that the drain line is in the 
tank and the float jack is plugged in.

V / Important Notes

A.

B.

Always keep the unit in an upright position, do not lay down. If the unit is laid down, the 
unit must be placed upright and not turned on for at least 4 hours, or compressor 
damage may occur, due to compressor oil displacement.

Filters should be changed as needed or at least once every 2 months. Remove filter 
from slot on top of unit by turning the 2 latch screws. The filter size is 12” x 12” x 1” 
(LxWxD)

If the air flow is blocked from the intake or exhaust grills the unit will go into alarm, due 
to high pressure on the compressor. Press the High Pressure reset button on the back 
of the unit, which will clear the alarm.

C.

Call 1-800-KWIKOOL (800-594-5665) for Service or Questions