background image

KWE P

/N 542 0

18 Ve

rsatronik 

COMO OT 

Q

ui

ck

 Sta

rt-Up 

V1.0

 01/

2009 Tec

hnic

al

 inform

at

io

subject

 to c

ha

nge

 without noti

ce 

Versatronik Como OT Quick Start-up 

Main Menu

User
Display
Time-Date
HTG-PROG1
HTG-PROG2

Expert

Holiday

HotWProg

Expert

Heatslope
Adaption
Room-Infl1
I-Control

N-Opt-Time

Max Opt-Time

Heat Up Opti

User:

T-Room Des1
T-Room Des2
T-Room Des3
T-Reduced

Max Modulati

Max T-HS

T-Absence

Return

C/F

HotWProg

Display:

T-Outside
T-Room
T-DHW
T-HS

Burner Start

Burner Time

Modulation

Return

Water Press

Time-Date Adjust

HTG-Prog2 Adjust

HTG-Prog1 Adjust

Time-Day
Time Selection
Day Selection

T-Room Adjust
Out-Temp-Del
Heatslope 2
Rooms-Infl2

English

Display

20

23

22

21

24
268-04
Return

Ä

 

Programming key   

a) Select a value level 

b) Select a value to be changed 
c) Saving the new value 

 

Plus key 

(Search for or change value) 

 

Minus key 

(Search for or change value) 

Menu Navigation 

Summary of Contents for Versatronik COMO OT

Page 1: ...use of flat blade screwdriver Tilt user interface from sub base by hinging from the top Mount sub base at desired location by utilizing field supplied fasteners through mounting holes Make wiring connections 1 Sub base OT communication terminals 1 and 2 2 Sub base Outdoor Temperature Sensor to terminals 5 and 6 3 Connect OT communication wires to Viessmann Vitodens X3 3 and X3 4 Tilt front of cont...

Page 2: ...om Des2 T Room Des3 T Reduced Max Modulati Max T HS T Absence Return C F HotWProg Display T Outside T Room T DHW T HS Burner Start Burner Time Modulation Return Water Press Time Date Adjust HTG Prog2 Adjust HTG Prog1 Adjust Time Day Time Selection Day Selection T Room Adjust Out Temp Del Heatslope 2 Rooms Infl2 English Display 20 23 22 21 24 268 04 Return Ä Programming key a Select a value level b...

Page 3: ...0C 68F Ð T ROOM DES2 20C 68F Ð T ROOM DES3 20C 68F Ð T REDUCED 20C 68F Ð T ABSENCE 20C 68F Ð MAX T HS 85o C 185o F Ð MAX MODULATI 80 Ð o C o F Select Ð RETURN EXPERT Settings Settings Ð HEATSLOPE 1 0 Ð ADAPTION 1 Ð ROOM INFL1 Ð l CONTROL OFF Ð HEAT UP OPTI 0 Ð MAX OPT TIME 0 3 2 00h Ð N OPT TIME Display only Ð T ROOM ADJUST 0 Ð OUT TEMP DEL 50C 122F Ð HEATSLOPE 2 0 Ð ROOMS INFL 2 Ð DISPLAY 0 1 0 Ð...

Page 4: ...OFF only frost protection function active F1 Automatic mode heating according to time program 1 F2 Automatic mode heating according to time program 2 F Summer mode heating OFF only hot water preparation active h Day mode Normal mode 24 hour heating at comfort temperature 1 C Night mode Reduced mode 24 h heating at economy temperature D F1 A B C E F I G H D J J A Current time B Set room temperature...