KVS MORAVIA TYPE 9114-HEU Operation & Maintenance Manual Download Page 4

The appliance should be installed by an authorised specialist. No claims are accepted 
in case of incorrect or amateur installation.

The TYPE 9114 appliance has been designed for solid fuel combustion in periodic feed rates and
it is intended for cooking and in households and/or for heating the space in which it is situated, ac-
cording to the ČSN EN 12815:2002 Standard as amended A1:2005 and Commission Regulation
(EU) 2015/1185 – eco design of solid-fuel local space heaters.
The appliance can be connected to a chimney from the top by means of a hole in the Hob top
(Drawing 1).  The appliance is suitable for short operational periods, so it is not possible to set the
permanent-heat process with a shortest interval of fuel supply of 10 hours.    

Appliance Characteristics

TYPE 9114-HEU

Energy efficiency class

A

Energy efficiency  index

104

Nominal heat output – NHO 

7.8 kW 

Direct heat output      

                                 

4.4 kW  

Indirect heat output

                            

3.4 kW

Efficiency at NHO

78.6%

(Seasonal efficiency

68.6%)

Average temperature of flue-gas at NHO

277 °C

Mass flow rate of flue-gas at NHO

7.1 g/s

Emissions during heating of spaces at NHO (with O

=13%):

PM

28 mg/m

3

OGC

83 mg/m

3

CO

1474 mg/m

3

No

x

99 mg/m

3

Minimum chimney draught

15 Pa

Preferred fuel

wood briquettes (pressed wood 
with moisture content < 12%)

Consumption of preferred fuel

2.1 kg/h

Weight

130 kg

Dimensions

 

Height of the worktop (distance from floor to hob top panel)

850 mm

Width of the appliance

515 mm

Depth of the appliance

575 mm

Diameter of the exhaust flue

120 mm

Area of the cooking range

0.2 m

2

TYPE 9114-HEU

     01/2016

3

Technical Specifications TYPE 9114-HEU

Summary of Contents for TYPE 9114-HEU

Page 1: ...TYPE 9114 HEU OPERATION MAINTENANCE MANUAL INSTALLATION MANUAL TYPE 9114 HEU 01 2016 0 SOLID FUEL RANGE COOKER WITH HOT WATER HEATER...

Page 2: ...f the baking accessories intended for contact with foodstuff under all normal conditions or by the stated use of the manufacturer comply with the requirements of Law No 258 2000 Coll the Ministry of H...

Page 3: ...h bins with covers Be very careful during the re moval of hot ash Pay attention to fire safety It is forbidden to use the appliance if it is damaged unfit for its function Any contravention of the ope...

Page 4: ...a shortest interval of fuel supply of 10 hours Appliance Characteristics TYPE 9114 HEU Energy efficiency class A Energy efficiency index 104 Nominal heat output NHO 7 8 kW Direct heat output 4 4 kW I...

Page 5: ...essure of the heat exchanger 2 bar Dimensions of the Fire Box Width x Height Depth 380 250 x 400 mm Fire grate Width Depth 160 290 mm Stokehole Width x Height 300 245 mm Accessories Poker 1 pc Glove 1...

Page 6: ...of the appliance Grate Grating This appliance has one grate The purpose of the grate is allowing the burned fuel to fall to the ashtray which increases the supply of combustion primary air to the comb...

Page 7: ...ns It is advised to check ventila tion issues with your local building control office to ensure trouble free operation Appliance Hob Top The single piece grounded steel finish hob top fotplate The hob...

Page 8: ...of stoking so that the final interval is once an hour The average fuel consumption is about 3 kg of fuel per hour Adding of fuel should be carefully done manually or by means of a suitable shovel Whe...

Page 9: ...mainder of the devices can be introduced later during the summer setting at least one heating device should be switched on for example a heating water tank as there should be water in the heat exchang...

Page 10: ...C bands bags plastic sheets recycle if available or dispose of sensibly Metal bands nails recycle The appliance contains valuable materials that can be recycled Your Local Authority or a licensed scra...

Page 11: ...rect operation as described in the operation manual 1 Production standards KVS MORAVIA solid fuel appliances are produced in accordance with the SN EN12815 2002 Standard with amended A1 2005 which is...

Page 12: ...rom hob top and to attach the flue branch The cooker can t be connected to a shared chimney Drawing 3 A chimney with a sufficient draught is absolutely essential for correct appliance operation We rec...

Page 13: ...ould overlap the protected material up to the nearest wall ceiling made of a fireproof material however not less than 300 mm at the upper side and 150 mm at the lateral sides We recommend that your in...

Page 14: ...ection with the expansion tank is used it is necessary to mount a safety valve of 1 8 bar and supply a reserve driving source for the pump in case of a failure in electricity supply The cooker cannot...

Page 15: ...Dimensional Sketch of the appliance TYPE 9114 HEU TYPE 9114 HEU 01 2016 14...

Page 16: ...Appliance Section TYPE 9114 HEU All of dimensions are in mm Connection of the appliance with expansion vessel TYPE 9114 HEU 01 2016 15...

Page 17: ...Installation schematic of the range cooker with a heat exchange unit within TYPE 9114 HEU 01 2016 16...

Page 18: ...the interior of a domestic dwelling TYPE 9114 HEU 01 2016 17...

Page 19: ...cer KVS EKODIVIZE a s Dvorce plant Opavsk 272 793 68 Dvorce u Brunt lu CZECH REPUBLIC phone 420 554 797 171 fax 420 554 745 500 email prodej dvorce kvs ekodivize cz www kvs ekodivize cz www kvs moravi...

Reviews: