64 | kvm-tec
6.1 rEQUIrEMEnTS For CaT5E/6/7 CablES
a cat5e/6/7 cable should meet the following requirements:
• The pins are connected 1:1.
Caution:
the cable pairs must be twisted to eIa/tIa- 568a (rare)
or eIa/tIa-568 b (common) pairs.
• Erroneous assignments cannot be found with a simple cable tester.
• The pins for the green pair of wires are not adjacent to one other.
• The cable must at the very least meet the CAT5 specifications and be suitable for Gigabit
transmission.
• The cable should meet one of the following standards: Class D ISO/IEC 11801:2002
or en 50173-1:2002. schema eIa/tIa-568 b.
• Only use shielded installation cable with min. cross section of 24 AWG throughout
the length.
• The shield should be contiguous and connected to both ends. A shielded patch cable is
allowed for connection to the device.
Schema EIa/TIa-568 b
6. REqUIREMENTS FOR CABLES
Pin
Color
1
orange
/White
2
orange
3
Green
/White
4
blue
5
blue
/White
6
Green
7
brown
/White
8
brown