![KVH Industries TracPhone V3IP Installation Manual Download Page 38](http://html1.mh-extra.com/html/kvh-industries/tracphone-v3ip/tracphone-v3ip_installation-manual_2013011038.webp)
37
8.
Gently flare the braid with your fingers (see
9.
Insert the end of the cable into the connector
body until the dielectric is firmly seated
inside the connector (see Figure 71). Make
sure there is no gap between the knurled end
of the connector and the cable jacket. Also be
sure all braid wires remain on the outside of
the connector.
10.
Trim any excess braid (see Figure 72), if
necessary. The braid should assemble flush to
within 1/16" (1.6 mm) of the connector
shoulder.
11.
Slide the ferrule over the braid until it is flush
against the connector shoulder (see
Figure 70: Flaring the Braid
Figure 71: Pushing On the Connector
A common installation failure occurs when
the connector is not seated properly onto the
cable. In these cases, the cable’s center
conductor does not fully engage the electrical
contacts inside the connector. To ensure full
engagement, make certain that there is no gap
between the cable jacket and the knurled end
of the connector before you crimp on the
ferrule. You may need to deburr and center
the end of the conductor to achieve a good fit.
IMPORTANT!
Figure 72: Trimming the Braid
Figure 73: Sliding the Ferrule Over the Braid
Continued
Terminating LMR RF Cables
A
Appendix
Summary of Contents for TracPhone V3IP
Page 46: ...54 0959 Rev A ...