1. Connect the RF cable tagged “RF1” to the
multiswitch input labeled “LNB RHCP +13V”.
2. Connect a second RF cable to the multiswitch
input labeled “LNB LHCP +18V”.
3. Connect the multiswitch outputs to individual IRD
inputs. Use RG-6 cable terminated with
F-type connectors for all RF connections.
4. Terminate all unused output connectors with
75 ohm DC blocks (Channel Master #7184, Radio
Shack #15-1259 or equivalent).
5.3
Replaceable Parts
Table 5-1 has been updated to include the dual-output LNB.
Part Name
Part Number
Radome Assembly
02-0953-02
Baseplate Assembly
02-0952-02
Power Cable
32-0590-30
Data Cable
32-0591-30
RF Cable
32-0589-30
EchoStar Adapter Unit *
02-0899
CPU PCB
02-1144-01
System Fuse
16-0017-3150
LNB
19-0056
* Optional, purchased separately
4
Table 5-1
Field Replaceable Units