Kvaser U100S-X2 User’s Guide
9 (24)
Figure 4: Not all devices are synchronized via MagiSync in this setup.
panel. If all your hardware is placed in one Kvaser MagiSync Group, then you are
ready to go.
When connected correctly, all units are synchronized achieving a high precision
virtual clock accurate to the microsecond.
3.4
CAN connection
The Kvaser U100S-X2 has one CAN channel.
The CAN connector for the Kvaser U100S-X2 is the 5-pole M12 plug (see Figure 5)
which has the pinning described in Table 2.
Figure 5: M12 5-pole CAN connector.
M12 pin number
Function
1
Shield
2
Not connected
3
GND
4
CAN_H
5
CAN_L
Table 2: M12 5-pole pin configuration.
Kvaser AB, Mölndal, Sweden — www.kvaser.com