![Kvaser LAPcan Hardware Manual Download Page 7](http://html.mh-extra.com/html/kvaser/lapcan/lapcan_hardware-manual_2012883007.webp)
Kvaser LAPcan / LAPcan II Hardware Guide
7(18)
Kvaser AB, Mölndal, Sweden — www.kvaser.com
5 Technical data, Kvaser LAPcan and Kvaser LAPcan II
CAN channels
2 (CAN 2.0A and 2.0B active)
CAN Transceivers
The transceivers are integrated into the DRVcans.
CAN Controllers
Philips SJA 1000
Microcontroller
Infineon C161O (16 MHz)
CAN Bitrate
5 kbit/s ... 1 Mbit/s
Timestamp resolution
8 microseconds
Error Frame Detection
Yes, both channels
Error Frame Generation
Yes, both channels
Hardware requirements
IBM PC AT or 100% compatible; PC-Card slot type II
or III
PC interface
PC-Card Version 2.0 (PCMCIA) or compatible
Current consumption
110 mA for the Kvaser LAPcan
plus the current of the
DRVcans
Software requirements
Windows 95 / Windows NT 4.0 or later
Configuration
Done by software (Plug & Play if OS supports it.)
Dimensions
PC-Card type II (ca. 85 mm x 64 mm x 5 mm)
Operating temperature
0 ºC ... +55 ºC
Non-operating
temperature
-25 ºC ... +70 ºC
Relative Humidity
0% ... 85% (non condensing.)