YES:
Is the Device Status indicator ON?
NO:
1. Check if there's a power in the socket
2. Check the main power fuse (find more
details in the Model Specific Information
Manual)
Is the Main Power Switch light ON?
OFF
Please check the
following:
1. The aperture
masking plate is open.
2. The main Safety Key
is in the slot and in ON
position.
3. The colour
adjustment pots are
turned all the way to
the right.
4. The system is not
overheated. Please
make sure there is
sufficient airflow
around the system and
the ambient
temperature is within a
range of 5-35 degrees
Celsius.
5. Your laser control
system is set up
correctly. Make sure
that there is a control
signal present.
YES
Are you using the Interlock
Connector or E-STOP
remote button?
Interlock Connector
The system
indicates there is a
problem with the
safety interlock:
1. Check that the
Interlock Connector
is inserted properly.
E-STOP remote
The system indicates there
is a problem with the safety
interlock:
1. Check that the E-STOP
Remote cable is inserted
properly at both ends and
that the safety key is
inserted and turned to ON
position.
2. Check that the red E-
STOP Remote is in ON
position - if not, pull it
upwards.
3. Press the RESTART
button on the E-STOP
NO
Is the ScanFail indicator
ON, OFF or it flashes?
ON or FLASHES
randomly
This indicates that the
ScanFail is active and
disables the laser
output:
1. check that the effect
you are running can
work in ScanFail safety
mode the laser is
switched to.
This could be a case of
you trying to output a
single beam or a very
small small picture from
the laser system whilst
the ScanFail safety is in
Scanner mode.
FLASHES periodically
This indicates the initial
60 second period of the
laser Emission Delay
safety feature:
1. Wait for about one
and half minutes and
the system should start
working.
Is the Device Status indicator ON?
YES
Please get in touch with your
KVANT laser supplier or our
technical support team:
[email protected]
+421 905 875 758
NO
Troubleshooting
The system should be working, but it isn't:
If none of above helps, please contact your local KVANT supplier or our technical support team:
/
+421 905 875 758
Page 12