About the Calibration Screens
KVAL Commander III Operation Manual
4-22
About Lock Plate Timing Calibration
Vertical:
If the vertical time is not making it up or down, before the horizontal move starts, enter a larger
number. This number is in seconds. If there is a delay before the horizontal moves, enter a smaller
number in this box.
Horizontal
:
If the Horizontal time is not making it left or right, before the vertical move starts, enter a larger
number. This number is in seconds. If there is a delay before the vertical moves, enter a smaller
number in this box.
Feed System Timing
Calibrates the In-feed and Out-feed timing of the door into the machine. Adjust until the Stop tim-
ing with the door is in synchronization.
Summary of Contents for Commander III
Page 46: ...About Revisions 2 16 KVAL Manual ...
Page 81: ...Common Terms 2 51 KVAL Manual FIGURE 2 11 Example of a Validation Report ...
Page 162: ...Options KVAL Commander III Operation Manual 5 20 ...
Page 165: ......
Page 166: ......
Page 167: ......