background image

VHD3200D · Important Safety Instructions 

VHD3200D A

mplifier  ·  I

mp

or

tan

t S

af

et

y I

nstr

uc

tions

Important Safety Instructions

Before using your VHD3200D Amplifier, be sure to carefully read the applicable items of these operating instructions  

and the safety suggestions. 

  1.  Read all product instructions.
  2.  Keep printed instructions, do not throw away.
  3.  Respect and rewiew all warnings.
  4.  Follow all instructions.
  5.  Do not use this unit near water, in unprotected out door areas or in rain or wet conditions.
  6.  Clean only with dry cloth.
  7.  Do not block any ventilation openings.
  8.  Install in accordance with KV2 Audio's recommended installation instructions.
  9.  Do not install near any heat sources such as heat radiators, heat registers, stoves or other apparatus that produce heat.
 10.  Do not defeat the safety purpose of the grounding type plug. A grounding type plug has two blades and a third    
 

  grounding connector. The third connector is provided for your safety. If the provided plug does not fit into your outlet,  

 

  consult an electrician for replacement of the obsolete outlet.

 11.  Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles.
 

  The AC mains plug or appliance coupler shall remain readily accessible for operation.

 12.  Only use accessories specified by KV2 Audio.
 13.  Unplug this Amplifier during lightning storms or when unused for long periods of time.
 14.  Refer all servicing to qualified service personnel. Servicing is required when the Amplifier has been damaged in any
 

  way, such as when the power-supply cord or plug has been damaged; liquid has been spilled or objects have fallen

 

  into the Vents; rain or moisture has entered the Amplifier; the Amplifier has been dropped; or when for undetermined  

 

  reasons the Amplifier does not operate normally.

 15.  Do not remove front or back panels. Removal of the panel will expose hazardous voltages.
 

  There are no user serviceable parts inside and removable may void the warranty.

 16.  An experienced user shall always supervise this professional audio equipment.  

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE PANELS.
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. 

WARNING: 

To prevent fire or electric shock, do not expose this equipment to rain or moisture. 

SAFETY SUMMARY
To reduce the risk of electric shock, disconnect the Amplifier from the AC mains before installing audio cable.
Reconnect the power cord only after making all signal connections. Connect the Amplifier to a two pole, three- wire
grounding mains receptacle. The receptacle must be connected to a fuse or circuit breaker. Connection to any other type
of receptacle poses a shock hazard and may violate local electrical codes. Do not allow water or any foreign object to get 
inside the Amplifier. Do not put objects containing liquid on or near the unit. To reduce the risk of overheating the Amplifier, 
avoid exposing it to direct sunlight. Do not install the unit near heat-emitting appliances, such as a room heater or stove.  
This Amplifier contains potentially hazardous voltages. Do not attempt to disassemble the unit. The unit contains no user
serviceable parts, repairs should be performed only by factory trained service personnel.

Summary of Contents for KVV 987 446

Page 1: ...develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source Our aim is to create audio products that absorb you place you within the performance and deliver a listening experience beyond expectations User Guide VHD3200D ...

Page 2: ......

Page 3: ... any way such as when the power supply cord or plug has been damaged liquid has been spilled or objects have fallen into the Vents rain or moisture has entered the Amplifier the Amplifier has been dropped or when for undetermined reasons the Amplifier does not operate normally 15 Do not remove front or back panels Removal of the panel will expose hazardous voltages There are no user serviceable pa...

Page 4: ...duction Dimensions 3 Getting Started 4 Unpacking Rack mounting Cooling AC Requirements 4 Front Panel 5 Rear Panel 6 7 Display menu description 8 Remote management 9 12 Overview 9 Channels 10 Diagnostics 11 Settings 12 Specifications 13 Warranty Service 14 Notes 15 16 ...

Page 5: ...ery highpowered device that can put out high voltages and sizable currents Always use safe operating techniques with the VHD3200D FOR YOUR SAFETY READ THE IMPORTANT PRECAUTIONS SECTION AS WELL AS THE INPUT OUTPUT AND POWER CONNECTION SECTIONS OF THIS MANUAL VHD3200D part number KVV 987 448 250V KVV 987 447 230V KVV 987 446 115V Application Specifically designed to drive all VHD ES SL subwoofer ele...

Page 6: ...D has a comprehensive cooling system featuring chassis sealed PCB board mounting and shock mounted speed controlled fans This means that the cooling system never drives air across PCB boards connectors or components ensuring prolonged electronic component lifespan and minimizing maintenance cycles Air is drawn into the front of the amplifier by the two fans on the rear panel this passes over the c...

Page 7: ...speaker protection limiter has been activated for that particular channel of the amplifier 3 Power ON Thermal Autoreset These are dual colour LED s When green they indicate that the Power Switch is ON and that channel of the amplifier is powered up When red they indicate that that channel has overheated and shut down The unit will Auto Reset after it cools down to a safe operating temperature 4 Mu...

Page 8: ...one channel One for each channel of the VHD3200D both must be connected to operate both channels of the VHD3200D They accept standard PowerCon terminated AC Mains cables 4 Fans The cooling fans operate continuously while the VHD3200D is on An internal temperature sensor increases the speed of the fans during high temperature conditions Air enters through the front grille and exits through the rear...

Page 9: ...rnal communication port supporting Ethernet standard accepts RJ45 T 658B wiring The VHD3200D provides web server and SNMP Simple network management protocol When the Ethernet cable is connected and devices successfully establish a connection the green LED is activated When Ethernet communication is in progress the orange LED flashes 8 Speaker AP4 Connectors One for each channel of the VHD3200D Acc...

Page 10: ...is pattern 169 254 x y where x and y are any two numbers between 0 and 255 Unlike DHCP Auto IP does not require a router or a separate server to assign an IP address Selected IP address is displayed on display section NET or can be obtained using KV2 diagtool software DHCP Dynamic Host Configuration Protocol A DHCP server enables network devices to request IP addresses and networking parameters au...

Page 11: ... Shows the information assigned by user of the amplifier Description Amplifier name Location Contact Uptime and Firmware revision Network status Shows the amplifier ethernet network address netmask mode and status Power Shows the amplifier power sources status Mains power A B Channel A B power sources Power over Ethernet PoE Temperature Shows the amplifier channel A B heat sinks temperatures and D...

Page 12: ...plifier diagnostics information Mains voltage Signal Green when input signal is present Speaker protection Orange when speaker protection hits Temperature Output voltage Shows the amplifier speaker output voltages Output current Shows the amplifier speaker output currents Calculated impedance Shows the amplifier speaker output connected speaker impedances 10 VHD3200D Remote management ...

Page 13: ...cs together Channel A B Sums amplifier channel diagnostics information Power source Temperature Health amplifiers A B working OK with dedicated gain Temperature Displays amplifiers heat sinks A B temperatures C Protection When red they indicate that that channel has overheated and shut down The unit will Auto Reset after it cools down to a safe operating temperature 11 VHD3200D Remote management ...

Page 14: ... identification Shows and sets the device local information Device name Location Contact Security Sets name and password for web server security default User name admin default Password admin Network Sets the Ethernet IP mode AutoIP DHCP default Static IP address and netmask must be set 12 VHD3200D Remote management ...

Page 15: ...tput Main Through OUT Speaker Output Speaker Output 2x AP4 1x AP4 bridge Features System setup Limiter Short protection Network Ethernet SMNP Webserver Power Power Connector 2x Neutrik PowerCon Operating Voltage 115V 230V 250V Operating Voltage Range 100 to 120V 60Hz 205 to 240V 50Hz 225 to 260V 50Hz Recommended Amperage 2 x 20A 115V 2 x 10A 230V 2 x 10A 250V Soft Start YES Protection Thermal brea...

Page 16: ...d distributor service centre or shipped directly to our factory Because of the complexity of the design and the risk of electrical shock all repairs must be attempted only by qualified technical personnel If the unit needs to be shipped back to the factory it must be sent in its original carton If improperly packed the unit may be damaged To obtain service contact your nearest KV2 Audio Service Ce...

Page 17: ...VHD3200D Notes 15 VHD3200D Notes ...

Page 18: ...VHD3200D Notes 16 VHD3200D Notes ...

Page 19: ......

Page 20: ...KVV120148 00 01 0 KV2 Audio International Nádražní 936 399 01 Milevsko Czech Republic Tel 420 383 809 320 Email info kv2audio com www kv2audio com The Future of Sound Made Perfectly Clear ...

Reviews: