KV2 Audio EX2.5 User Manual Download Page 5

EX2.5 USER GUIDE 

P. 5

Make sure that even with the AC voltage drop, the AC 
voltage always stays within recommended operating 
ranges. The minimum electrical service amperage 
required by a EX2.5 speaker system is the sum of each 
loudspeaker’s maximum continuous rms current. An 
additional 50 percent above the minimum amperage 
is recommended to prevent peak volt-age drops at 
the service entry.

The Power Connector

The EX2.5 requires a grounded outlet. It is very 
important that the loudspeaker AC supply be prop-
erly grounded in order to operate safely and 
correctly. Use the PowerCon AC cable-wiring diagram 
on page 5 to create international or special-purpose 
power connectors:

Current Requirements

Each EX2.5 requires approximately 15 Amps max at 
115V AC for proper operation. This allows one EX2.5 
to be powered from one 15 A breaker at 115 V and up 
to 2 EX2.5 subwoofers at 230 V or 250V. 

The EX2.5 presents a dynamic load to the AC mains, 
which causes the amount of current to fluctuate 
depending on quiet or loud operating levels. Since 
different cables and circuit breakers heat up at 
varying rates, it is essential to understand the types of 
current ratings and how they correspond to circuit 
breaker and cable specif cations.

The maximum long-term continuous current 
consumption is the maximum rms current during a 
period of at least ten seconds. It is used to calculate 
the temperature rise in cables, in order to select a 
cable size and gauge that conforms to electrical code 
standards. It is also used to select the rating for slow-
reacting thermal breakers.

The burst current consumption is the maximum rms 
current during a period of approximately one second, 
used to select the rating of most magnetic breakers 
and to calculate the peak voltage drop in long AC 
cables according to the formula: V pk (drop)= I pk x R 
(cable total).

The ultimate short-term peak current is used to select 
the rating of fast reacting magnetic breakers. Use the 
table below as a guide when selecting cable gauge 
size and circuit breaker ratings for your operating 
voltage.

AC Cable Color Coding

If the colors referred to in the diagram don’t corre-
spond to the terminals in your plug, use the following 
guidelines:

Connect the blue wire to the terminal marked with a N or 
colored black. Connect the brown wire to the terminal 
marked with an L or colored red. Connect the green and 
yellow wire to the terminal marked with an E  or colored 
green or green and yellow.

AC POWER REQUIREMENTS

CAUTION

: The EX2.5 requires a ground 

connection. Always use a grounded outlet 
and plug.

Current Draw

115 V Mode 230 V, 250V

Max. Long Term Continuous 15 A rms

7.5 A rms

Burst Current

22 A rms

11 A rms

Short Term Peak

60 A peak

30 A peak

 GREEN / YELLOW

Power connector assembly

Power cable color coding

Summary of Contents for EX2.5

Page 1: ... develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source Our aim is to create audio products that absorb you place you within the performance and deliver a listening experience beyond expectation EX2 5 User Guide ...

Page 2: ...AC POWER 4 Voltage Requirements 4 The Power Connector 5 Current Requirements 5 AC Cable Color Coding 5 IMPORTANT SAFETY INSTRUCTIONS 6 SAFETY SUMMARY 6 EX1 8 CONTROL PANEL 7 REAR CONTROL PANEL 7 Audio Input and Output 7 Amplifiers and Acoustic Filters 8 LED Status Lights 8 Power On Thermal LED 8 Signal 8 Limiter 8 Phase Switch 8 Level Control 8 EX2 5 DRAWING 9 EX2 5 SPECIFICATIONS 10 EX2 5 ACCESSO...

Page 3: ...control This is especially true under typical phase shift conditions in which the amount of the current requirement is sometimes doubled Through the implementation of a proprietary switch mode ampli fier technology the EX2 5 amplifier provides extremely high efficiency with low losses and delivers the highest woofer control by delivering higher current levels under phase shift conditions The new c...

Page 4: ... PO QPMF NBJO TZTUFN with locking connectors to prevent accidental discon OFDUJPO 5IF NBJO CMVF DPOOFDUPS TFSWFT BT UIF QPXFS JOQVU HSFZ DPOOFDUPS TFSWFT BT QPXFS PVUQVU NBY XIFO SVOOJOH PO 7 XIFO SVOOJOH PO 7 PS 7 5IF 9 PQFSBUFT JO FJUIFS 7 7 PS 7 NPEFT MUIPVHI QSF DPOG JHVSFE BU UIF GBDUPSZ UIF unit s operating voltage mode can be changed in the field Voltage Requirements The EX2 5 operates safe...

Page 5: ...tion is the maximum rms current during a period of at least ten seconds It is used to calculate the temperature rise in cables in order to select a cable size and gauge that conforms to electrical code standards It is also used to select the rating for slow reacting thermal breakers The burst current consumption is the maximum rms current during a period of approximately one second used to select ...

Page 6: ...rms or when unused for long periods of time 15 Refer all servicing to qualifed service personnel Servicing is required when the loudspeaker has been damaged in any way such as when the power supply cord or plug has been damaged liquid has been spilled or objects have fallen into the loudspeaker rain or moisture has entered the loudspeaker the loudspeaker has been dropped or when for undeter mined ...

Page 7: ...l load impedance presented by the paralleled input circuit of the array Main Input Signal applied to the left channel Main Input is summed with any signal applied to the right channel Main Input and then fed to the EX2 5 amplifier When using the EX2 5 with a mono signal then either Main Input can be used Mid Hi Output Signal applied to either Main Input also passes through a stereo crossover This ...

Page 8: ...hanges the phase of the high pass audio output signal Changing the phase of the output signal serves as a tool for integrating the full range cabinet and the subwoofer into challenging audio environments We recommend using a suitable measuring device for performing relevant measurements and determining whether the phase should be reversed Level Control The EX2 5 features a rotary control knob prov...

Page 9: ...EX2 5 USER GUIDE P 9 EX2 5 DRAWING ...

Page 10: ...Low Frequency Amplifier Specification Type High efficiency Low frequency Current enhancing switch mode Rated Continuous Power 1600W Distortion 0 05 Operating Bandwidth 34Hz 125Hz Speaker Input Speaker Input EP4 Signal Input Input Channels 2 Input Sensitivity 1 0V RMS Input Impedance 20kΩ balanced Signal Output Output channels Mid High Through Features Level Control 6 6dB Phase 0 180 RMS Limiter YE...

Page 11: ...R GUIDE P 11 EX2 5 ACCESSORIES SYSTEM 1 One EX12 with a single EX2 5 MkII SYSTEM 2 One EX12 with a single EX2 5 MkII driving a single passive ES2 6 subwoofer SYSTEM 3 Two EX12 s with a single EX2 5 MkII SYSTEM 4 Eight EX6 s with a single EX2 5 MkII SUGGESTED SYSTEMS Front mount magnetic cart for ES1 8 ES2 5 ES2 6 EX2 5 MkII part name CRT 0009 part number KVV 987 114 wheels not included Cart Wheels...

Page 12: ...w kv2audio com KVV120007 00 03 0 At KV2 Audio our vision is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source Our aim is to create audio products that absorb you place you within the performance and deliver a listening experience beyond expectation ...