Setting The CT Value
Set the 5 pin dip switch for the CT (Current Transformer) and the
system phase you are using.
Dip Switch Setting Reference Diagram
Specification
ITEM
DESCRIPTION
DC Supply
9.0 ~ 36 V
Alternator Input Range
10 ~ 500VAC(Ph-Ph)
Alternator Input Frequency
50/60 Hz
CT Burden
Above 2.5VA
CT Secondary
5A
Max. CT Rated
3000A / 5A
Operating Temperature
-20
C to
70
C
Relative Humidity
90% or Below
Power Consumption
Under 2W
Weight
200 gram
Three Phase System Standard Wiring Diagram
Single Phase System Standard Wiring Diagram
Please link to
http://www.kutai.com.tw
for detailed manual
Battery
F4
+
1A
L1
J1-2
L3
L2
J1-6
J1-4
G
0.5A
F3
0.5A
0.5A
F1
F2
L1
L2
L3
L1
CT-L1
J2-15
DSP-30 Meter
J2-8
J2-9
V-
V+
J2-12
J2-13
J2-14
K
L
K
K
L
CT-L2
L
CT-L3
L3
L2
LOAD
50/5A
100/5A
150/5A
200/5A
250/5A
300/5A
400/5A
500/5A
600/5A
800/5A
1000/5A
1200/5A
1500/5A
1600/5A
2000/5A
3000/5A
Programmer Table
=ON
=OFF
System Phase select
5
= 3 Phase
5
= 1 Phase
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
Current Transformer (CT)
J1-2
J1-4
F4
1A
V+
J2-8
J2-9
V-
F2
0.5A 0.5A
F1
L2
L1
J2-12 J2-15
L1
K
L
CT-L1
L1
L2
DSP-30 Meter
LOAD
G
L2
Battery
+