background image

 

___________________________________________________________________________________________

 

CH46

 

CH4612 & CH4624

 

Automatic Battery Charger user manual 

 

 

 
 
 
 
 
 
 

GENERAL INFORMATION 

A visual inspection of this product for damage during 
shipping is recommended before installation. Please 
contact your local supplier with any questions. 

SECTION 1: IMPORTANT SAFETY 
INSTRUCTIONS

 

This manual contains important safety and operating 
instructions for battery charger Models CH4612 and 
CH4624. Read the manual carefully and follow the 
instructions before using your charger. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.1  This is not a power supply. Use only as a battery 

charger. 

1.2  Built-in AC power fuses protected input. No 

external fuses are needed. Do not attempt to 
replace internal fuse, if it burns out. 

1.3  Do not expose the battery charger to rain, snow 

or wet environments. 

1.4  Do not disassemble the charger. Return to 

supplier when service and repair is needed..   

1.5  Be very careful not to drop any metal tool on to 

the battery or charger. It may spark or short-circuit 
the battery or other electrical part, which in turn 
may cause an explosion. 

1.6  To reduce the risk of damage to the electric plug 

and cord, pull using the plug rather than the cord 
when disconnecting the charger. 

1.7  If battery acid or chemicals contact skin or 

clothing, wash immediately with soap and water.   

1.8  If battery acid or chemicals comes into contact 

with your eye, immediately begin washing your 
eye with cold water before taking any other action 
and continue for at least 10 minutes. Get 
immediate medical attention. 

 

SECTION 2: SPECIFICATIONS 

 

Power Input 

Protection 

 

 

Voltage 

100 

 277 Vac 

  Constant output voltage, limited charge current 

Reverse polarity & short circuit protections.

 

 

Frequency 

47 

 63 Hz

 

Environment

 

DC Output 

 

Operation Temperature 

-20 to 

+60 ˚C

 

 

CH4612 

Voltage 13.8 Vdc / Current    5A Max. 

 

Storage Temperature 

-30 to +80 

˚C

 

 

CH4624 

Voltage 27.6 Vdc / Current    3A Max. 

 

Relative Humidity 

Max. 90%

 

DC Voltage Regulation 

 

Vibration 

5.0Gs @ 60 Hz

 

<

 

+/- 1% 

Mounting Type

 

Charge Mode 

Panel or DIN Rail Mount

 

Float

 

Dimensions

 

Efficiency 

 

175.0 (L) x 115.0 (W) x 60.0 (H) mm 

> 80% @ Full load

 

     

7” (L) x 4.5” (W) x 2.4” (H) 

Low Battery Voltage Alarm Output Capacity 

Weight

 

Solid State 0.5A @ 40 Vdc

 

0.52Kg (1.15Lbs) +/- 2% 

Suitable Battery Type 

UL Listed   

Gel, Lead Acid & AGM 

File No. E471849

 

 

 

DANGER! 

High Voltage may result in a risk of fire, electric 
shock, injury or death 

WARNING! 

Batteries may generate explosive gases during 
normal operation and charging. Never smoke, 
light a flame, or generate any sparks near the 
battery. 

Reviews: