background image

 
 
 
 

 

 

 
 

CH10 CH11 CH20 CH21

 

Automatic Battery Charger User’s Guide 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

Kaohsiung : 

No.3, Lane 201, Chien Fu ST., Chyan Jenn Dist., Kaohsiung, TAIWAN 

Tel : + 886-7-8121771 

Fax : + 886-7-8121775 

URL : 

http://www.kutai.com.tw 

Email : 

[email protected]   

 

Summary of Contents for CH10

Page 1: ...CH20 CH21 Automatic Battery Charger User s Guide Kaohsiung No 3 Lane 201 Chien Fu ST Chyan Jenn Dist Kaohsiung TAIWAN Tel 886 7 8121771 Fax 886 7 8121775 URL http www kutai com tw Email service mail kutai com tw ...

Page 2: ... 1 Ensure the type and output voltage before power on 2 2 Connect charger line accessory with terminals Warning terminals should not be shorted 2 3 Plug in then switch on voltage meter should be read by 13 8V 12V 27 6V 24V 2 4 If output voltage correct then power off Connect the red side of the charger line to the terminal of the battery the black one to the terminal 2 5 Power on then charging is ...

Page 3: ...r 3 3 Never depart the charger 3 4 Never change internal wiring of the charger 3 5 Never adjust internal VRs of the PCB intentionally 3 6 Routine check of output voltage is necessary 3 7 Terminals of the charger and polarities of the battery should be connected correctly red to black to Warning Never short red terminal and black terminal polarities 3 8 Please operate the charger under the max maxi...

Page 4: ...heck if battery is full charged or not 2 Check if poor connection exists or not 3 Check if the type and the rate of the charger are correct or not No charge current or current Can t be adjusted 4 Check if battery is out of order or not If the step above can t make the charger working still please contact with us 1 Voltage Meter 2 Current Meter 3 Voltage Adjustment VR inside mounted 4 Current Adjus...

Reviews: