A.C. POWER
BATTERY
+
-
THERMISTOR
(OPTIONAL)
Figure 2
INSTALLATION WIRING
NOTE: This charger is designed to have it’s output voltage compensated for changes in
Temperature. A switch on the circuit board selects whether the unit is operated in the
compensated or uncompensated mode. WHEN IN THE TEMPERATURE COMPENSATED
MODE THE THERMISTOR MUST BE CONNECTED. Operation without the thermistor
while in the compensated mode will result in loss of voltage control and overcharging
of the battery.
NC
COM
NO
UV RELAY Customer Interface
(Optional)
White
Green
Black
OUTPUT
CURRENT
HIGH/LOW
SWITCH
(OPTIONAL)
Summary of Contents for AUTO CHARGE 091-127 Series