INSTRUCTION MANUAL
Specifications:
Operating Temp:
0 to 50°C
(32 °F to 122 °F)
Dimensions:
2”W x 2.5”H x
1.38”D (50.8x 63.5 x
35.2 mm)
Weight:
0.125 lb. (0.05 kg)
Wiring Diagram
File: IM_091-269-00
6
Rev: A
1
Revised By: PSS/jrn
Date:
12
-
10
-
20
19
MODEL: 091-269-00
6
The Auto Power Remote Panel comes
with a 25-ft (7.6-m) communications cable.
Important Safety Information
Misusing or incorrectly connecting the remote panel may damage
the equipment or create hazardous conditions for users. Read the
following safety instructions and pay special attention to all Caution
and Warning statements in your Auto Power Inverter Owner’s Guide.
Warnings
1. All electrical work must be done in accordance with local, national, and/or inter-
national electrical codes.
2.
All electrical work must be done by a qualified installer.
3. Before installing or using the remote panel, read all instructions and cautionary
markings located in the manual, on the Auto Power unit, and on the batteries.
4. Do not expose the remote panel to rain, snow or liquids of any type. This prod-
uct is designed for indoor mounting only.
5. Use insulated tools to reduce the chance of short- circuits when installing or
working with the inverter/ charger, or the batteries.
6. Remove all jewelry such as rings, bracelets, necklaces, etc., while installing
this system. This will greatly reduce the chance of accidental exposure to live
circuits.
7. The Auto Power Inverter/Charger contains more than one live circuit (batteries
and AC power). Power may be present at more than one source.
8. he remote panel contains no user-serviceable parts. Do not attempt to repair
this unit.
Failure to follow these safety guidelines may cause personal injury and/or damage to
the remote panel. It may also void your product warranty
Mount the remote panel in a clean, dry environment.
To install the remote panel:
1. Choose a location that is dry, free from cor-
rosive or explosive fumes, and appropriate
for installing an electronic device.
2. Using the mounting template (provided), pi-
lot-drill the mounting holes. Cut an opening
about 2×1.2 in. (50.8×30.5 mm) and 1.4 in.
(35 mm) deep.
3. Route the communications cable inside the
wall and through the opening to the Auto
Power unit.
4. Connect the communications cable to the
RJ11 Com Port on the back of the remote
panel.
5. Select whether to enable or disable the
Ignition
6. If you enable the Ignition Lockout feature,
connect the remote’s red ACC wire to the
vehicle’s ACC wire (12-volt connection only).
Consult your vehicle’s Owner’s Manual for
information.
7. Position the remote into the opening in
the wall and secure it with the four screws
(provided).
8. Make sure to switch the inverter OFF.
9. Plug the communications cable into the
remote port (REM) on the Auto Power unit.
Mounting the Unit
The Auto Power Remote Panel (remote panel) can be connected to the Auto Power Inverter Charger via the Remote
port on the AC/DC side panel to turn the Auto Power 2000 or 3000 Inverter Charger ON or OFF from a more convenient lo-
cation. The remote panel also has the ability to enable/disable the Ignition Lockout feature of the Auto Power Inverter Char-
ger. When this feature is enabled, the Auto Power Inverter Charger will shut down if The Auto Power Remote Panel (remote
panel) can be connected to the Auto Power Inverter Charger via the Remote port on the AC/DC side panel to turn the Auto Pow-
er 2000 or 3000 Inverter Charger ON or OFF from a more convenient location. The remote panel also has the ability to enable/
disable the Ignition Lockout feature of the Auto Power Inverter Charger. When this feature is enabled, the Auto Power Invert-
er Charger will shut down if the vehicle’s ignition is not engaged (not in ACC position) to prevent unnecessary battery drain.
(For AP 2000 and 3000 Inverter/Chargers)
AUTO POWER
REMOTE PANEL ON/OFF SWITCH