WIRING
I. BATTERY CHARGER WIRING INSTRUCTIONS
1.
Refer to Installation Wiring Diagram I. and II.
2.
Refer to Wiring Specifications to determine the recommended wire size and maximum lengths.
Using a smaller gauge may cause overheating of the terminal. Additional information is available
upon request if longer, larger wiring is required.
3.
Double check all wiring before applying AC power to input terminal.
4. Apply AC power (shoreline power) to input terminal and observe that the charger is operating.
5. Verify that the battery voltage appears at the charger output terminals. A minimum of 9 volts is
required to start the charger.
II. WIRING SPECIFICATIONS
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
5
Length of Wire to Battery (feet)
Battery Charger Connections
V.
BA
T +
AU
X +
CO
M
-
V.
BA
T +
AU
X +
CO
M
-
V.
BA
T +
AU
X +
CO
M
-
Wire # Gauge (awg)
10
12
10
10
12
10
10
12
10
Wire Ferrule Used
09
1-
TE
RF
EY
10
12
09
1-
TE
RF
EG
12
12
09
1-
TE
RF
EY
10
12
09
1-
TE
RF
EY
10
12
09
1-
TE
RF
EG
12
12
09
1-
TE
RF
EY
10
12
09
1-
TE
RF
EY
10
12
09
1-
TE
RF
EG
12
12
09
1-
TE
RF
EY
10
12
0-5
5 - 10**
10 - 20*
* Consult factory if length of wire to battery is longer than 20 feet
** Supplied with wire terminal hardware for 10 foot installation