background image

3.250 2.125

1.875

3/16” 

DIA HOLE

2  1/4

” DIA HOLE

DRILL THESE TWO HOLES FIRST
1/2” DIA HOLE

C

L

L

C

C

L

L

C

Hole Template

AUTO EJECT

DYNAMIC DISCONNECT

AUTO EJECT

ENCLOSURE

MODEL # 091-18-098

The Model 091-18-098 Dynamic Disconnect is a
coupling device wired between an Auto Eject and the
vehicle and serves to only connect the A.C. power
after the plug has been inserted into the Auto Eject.
Upon vehicle startup the Dynamic Disconnect opens
the load circuit before ejecting the plug. By providing
the time delays on both application and removal of
power, no arcing can occur at the connector. Note
A.C. power must be present at the shore line connec-
tor in order to operate the Dynamic Disconnect.

The Enclosure is fabricated from aluminum and
contains a cutout and captive fasteners to mate with
the Auto EJect mounting screws. Providing protec-
tion from road dirt and damage, this unit suggested
for all Auto Eject installations in which the mecha-
nism is exposed to the elements or subject to
damage.

MODEL # 091-18CP

Summary of Contents for 091-18WP

Page 1: ...1 YEAR WARRANTY KUSSMAUL ELECTRONICS CO INC 170 CHERRY AVE WEST SAYVILLE N Y 11796 1221 2 10 00 file 091 18WP XX TEL in NY 631 567 0314 TOLL FREE 800 346 0857 FAX 631 567 5826 AUTO EJECT WP AUTOMATIC SHORE LINE DISCONNECT ...

Page 2: ...only while the engine is cranking If the solenoid is energized continuously it will OVERHEAT and BURN OUT If the AUTO EJECT is installed where the rear mechanism can accumulate dirt grime or water you must install a 091 18CP Rear Enclosure FAILURE TO FOLLOW THESE CAUTION NOTES WILL VOID THE WARRANTY ...

Page 3: ...nect the Green Black and White power wires to the accessories on the vehicle 6 Test installation by installing mating connector into the AUTO EJECT Energizing the starter should energize the solenoid and eject the connector 7 Keep connector and contacts of the AUTO EJECT clean Clean contacts with WD 40 solvent as required Lubricate contacts monthly with vaseline to insure free operation NOTE USE O...

Page 4: ...rtup the Dynamic Disconnect opens the load circuit before ejecting the plug By providing the time delays on both application and removal of power no arcing can occur at the connector Note A C power must be present at the shore line connec tor in order to operate the Dynamic Disconnect The Enclosure is fabricated from aluminum and contains a cutout and captive fasteners to mate with the Auto EJect ...

Page 5: ...y material or defects which become apparent in normal use within 1 years from the date the equipment was shipped Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The purchaser by the acceptance of the equipment assumes all liability for any damages which...

Reviews: