background image

3

INSTALLATION

The Auto Charge Dual 12 Volt-10 Amp  Automatic Battery Charger should be installed in an

area with  adequate ventilation. Wiring is illustrated in figure 1 and figure 2.

1. Mount the charger using the four holes provided for this.

2. Connect the wiring from the batteries to the Output Terminal Strip.

3. Double- check all wiring before proceeding.

4. Connect the A.C. power through the provided line cord (attached to the charger).

5. Pilot light will show that the charger has power.

Figure 2 illustrates this charger connected to two batteries in series. Each battery is
individually charged and charging ceases automatically when that battery is fully charged.
Thus if battery 1 requires more charging due to the accessory load, charging to battery 1 will
continue even after charger 2 has stopped charging battery 2. This ensures that both
batteries will be fully charged but neither will be over-charged.

Summary of Contents for 091-145

Page 1: ...EL 091 145 TEL in NY 631 567 0314 TOLL FREE 800 346 0857 FAX 631 567 5826 3 YEAR WARRANTY INPUT 120 Volts 50 60 Hz AC OUTPUT 1 12 Volts DC Isolated OUTPUT 2 12 Volts DC Isolated KUSSMAUL ELECTRONICS CO INC 170 CHERRY AVE WEST SAYVILLE N Y 11796 FILE 091 145 DATE 01 02 02 ...

Page 2: ... battery and is electrically isolated from the other Two seperate ammeters indicate the output current to each battery Construction of the Auto Charge Dual 12 volt 10 Amp Battery Charger is extremely rugged to withstand the shock and vibration encountered in vehicle mounted equipment Each output operates completely automatically and stops charging its battery when the battery is fully charged Ther...

Page 3: ...ng 4 Connect the A C power through the provided line cord attached to the charger 5 Pilot light will show that the charger has power Figure 2 illustrates this charger connected to two batteries in series Each battery is individually charged and charging ceases automatically when that battery is fully charged Thus if battery 1 requires more charging due to the accessory load charging to battery 1 w...

Page 4: ...4 2INDIVIDUALBATTERIES Figure 1 INSTALLATION ...

Page 5: ... THE TWO 12 VOLT BATTERIES PRODUCES 24 VOLTS EACHBATTERYISINDIVIDUALLY CHARGED AT 12 VOLTS THUS EVEN THOUGH THE BATTERIES MAY SUPPLY DIFFERENT LOADS EACHBATTERYISAUTOMATICALLY SUPPLIED WITH THE CORRECT CHARGING CURRENT WHEN EACH OF THE BATTERIES IS FULLY CHARGED IT S CHARGER STOPS CHARGING ...

Page 6: ...put Voltage 115 VAC 50 60 Hertz Input Fuse 8 Amperes normal blow Input Current 5 Amperes A C Output Voltage Dual 12 volt outputs Output Current 10 Amperes D C per output Charge Indicators 0 to 15 Amperes per output Weight 22 lbs ...

Page 7: ... use within 3 years from the date the equipment was shipped Equipment is to be returned shipping charges prepaid and will be returned after repair shipping charges paid Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The purchaser by the acceptance of t...

Reviews: