Model KM-CAL-802

ELECTRICAL SPECIFICATIONS - KM-CAL-802

í

 Basic Accuracy :

 ± 0.05%

í

 Display :

  5 Digit LCD display.

í

 Max. Allowable Voltage : 

30V..

í

 Operating Temperature Range :

 0 ~ 50°C. 

     

Humidity range :

 

£ 

80% RH

í

 Storage Temperature Range :

 

£

 

-10°C ~ 55°C  

     

Humidity range :

 

£ 

90% RH

GENERAL SPECIFICATIONS

This  is  a  Thermocouple  “Source”  &”Sink”  Calibrator.  It  gives  output  of  DC  Volts 

 & output for R, S, B, E, K, J, T & N Thermocouples.  It measures DC Voltage & also 

R, S, B, E, K, J, T & N Thermocouples.   It has 5 digit LCD display & extremely high 

accuracy 0.05%.

í

 Temperature Coefficient :

  0.1 x (dedicated Accuracy) % / 

      °C (5°C ~ 18°C, 28°C ~ 40°C)

í

 Power Consumption :

 about 50m / 3V.

í

 Dimension  :

  180 (L) x 90 (W) x 47 (D) mm (with protector)

í

 Weight : 

About  500g

í

 Power :

  1.5V x 2 alkaline batteries.

ACCESSORIES :

User  Manual, Test lead CF-36, (Clips for probe), 

Holster & Carrying case.

SAFETY : 

Complies with IEC1010 (safety standard issued 

by International Electrician Committee)

NEW

OUTPUT  FUNCTION

100mV

R

S

B

E

K

J

T

N

-10.00 ~ 110.00mV

O

-40 ~ 1760 C

O

-20 ~ 1760 C

O

400 ~ 1800 C

O

-200.0 ~ 1000.0 C

O

-200.0 ~ 1370 C

O

-200.0 ~ 1200.0 C

O

-200.0 ~ 400.0 C

O

-200.0 ~ 1300.0 C

0.01mV

O

1 C

O

1 C

O

1 C

O

0.1 C

O

0.1 C

O

0.1 C

O

0.1 C

O

0.1 C

±0.05% ± 30

m

V

O

±0.05% + 3(Less than or equals to 100 C)

O

±0.05% + 2(more than 100 C)

The max. Output
current ± 2mA

Employs ITS-90

temperature

standard 

The accuracy does not 

include the error of 

interior temperature

compensation sensor

The accuracy does not

include the impact of 

interior thermoelectric

force.

DC Voltage

Thermo-
couple

Output

Remarks

 

Accuracy

Output Range

Resolution

Range

1V

-0.1000 ~ 1.1000V

0.1mV

±0.05% ± 30mV

RTD

O

±0.05% + 3(Less than or equals to 600 C)

O

±0.05% + 2(more than 600 C)

O

±0.05% + 20 (Less than or equals to -100 C)

O

±0.05% + 10 (more than -100 C)

INPUT  FUNCTION

100mV

-10.00 ~ 110.00mV

0.01mV

±0.05% ± 3

Input Resistance : 1M

W

DC Voltage
DCmV

Output

Remarks

 

Accuracy

Output Range

Resolution

Range

R

S

B

E

K

J

T

N

O

-40

 ~ 1760 C

O

C

O

-200

 ~ 1760 C

O

C

O

400

 ~ 1800 C

O

C

O

-200.0

 ~ 1000.0 C

O

C

O

-200.0

 ~ 1370 C

O

C

O

-200.0

 ~ 1200.0 C

O

C

O

-200.0

 ~ 400.0 C

O

C

O

-200.0

 ~ 1300.0 C

O

C

O

1 C

O

1 C

O

1 C

O

0.1 C

O

0.1 C

O

0.1 C

O

0.1 C

O

0.1 C

O

±0.05% + 3(Less than or equals to 100 C)

O

±0.05% + 2(more than 100 C)

Employs ITS-90

temperature

standard 

The accuracy does not 

include the error of 

interior temperature

compensation sensor

The accuracy does not

include the impact of 

interior thermoelectric

force.

Thermocouple
TC

O

±0.05% + 3(Less than or equals to 600 C)

O

±0.05% + 2(more than 600 C)

O

±0.05% + 20 (Less than or equals to -100 C)

O

±0.05% + 10 (more than -100 C)

Input Resistance : 1M

W

Summary of Contents for KM-CAL-802

Page 1: ...R S B E K J T N 10 00 110 00mV O 40 1760 C O 20 1760 C O 400 1800 C O 200 0 1000 0 C O 200 0 1370 C O 200 0 1200 0 C O 200 0 400 0 C O 200 0 1300 0 C 0 01mV O 1 C O 1 C O 1 C O 0 1 C O 0 1 C O 0 1 C...

Page 2: ...Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator P...

Page 3: ...hich is extreme dangerous Never apply voltage exceeding 30V between any two terminals and earth ground terminals Caution Do not open the meter s case except for the professional technicians Use a damp...

Page 4: ...nt calibrated zero point or full point when the meter is in calibration state e RJ ON indicates the meter has undergone cold junction compensation work See detailed section indicates the batteries are...

Page 5: ...the batteries The meter is powered by two LR6 alkaline batteries AA Warning To avoid electrical shock or personal injury Remove test leads from the meter before opening the battery door Close and lat...

Page 6: ...t See the detailed section Section Five Output of the Meter The meter generates DC current or thermocouple simulate temper ature by the Users from the corresponding output terminals OUTPUT Caution Do...

Page 7: ...eed to wait for 2 seconds when starting the interior cold junction compensation of the meter and the meter will make automatic compensation every 10 seconds When the operation ambient temperature chan...

Page 8: ...2 Press INPUT OUTPUT key and the LCD displays INPUT indicating the meter is in input state 3 Press FUN key select thermocouple TC function and display 1 C unit and R graduation no 4 Press RANG a key...

Page 9: ...ain Output Range Output range Resolution Accuracy Illustration DCV 100mV 10 00 110 00mV 0 01mV 0 05 30uV max output Current 2mA 1V 0 1000 1 1000V 0 1mV 0 05 0 3mV R TC 40 1760 C 1 c S 20 1760 C 1 c 0...

Page 10: ...C The accuracy does not include the error of interior temperature compensation sensor The accuracy does not include the impact of interior thermoele ctric foece weight about 500g accessory User s Manu...

Page 11: ...r end user customer of a KUSAM MECO authorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MEC...

Reviews: