MODEL - KM 888PMR

PHASE & MOTOR 

ROTATION INDICATOR

OPERATION MANUAL

Summary of Contents for KM 888PMR

Page 1: ...ai 400 015 INDIA Sales Direct 022 24156638 Tel 022 24124540 24181649 Fax 022 24149659 Email kusam_meco vsnl net Website www kusamelectrical com www kusam meco co in AN ISO 9001 2008 COMPANY MODEL KM 888PMR PHASE MOTOR ROTATION INDICATOR OPERATION MANUAL ...

Page 2: ... SAFETY CHECKS DON T TOUCH GENERAL DESCRIPTION BRIEF PRODUCT DESCRIPTION OPERATING INSTRUCTIONS FRONT PANEL LAYOUT PRINCIPLE OF HOW IT WORK PREPARATION FOR USE REPLACING THE BATTERIES FUSE REPLACEMENT SPECIFICATIONS TEST CERTIFICATE WARRANTY 01 02 02 03 04 04 06 07 08 08 08 09 10 11 ...

Page 3: ...hand to hand contact between the tester and extended test leads When using the tester with test leads ensure that they are safe and properly authorized Disconnect the tester from any external circuit when changing the batteries CAUTION READ THE MANUAL Follow the instructions in the Manual for every measurement Read and understand the general instructions before attempting to use this tester SAFETY...

Page 4: ... winding is connected to the terminals of the Motor when the rotation Leds light up BRIEF PRODUCT DESCRIPTION This 3 Phases and Motor Rotation Tester has 3 test leads which connects to the 4 mm female sockets on the tester on the one side These Test leads are color coded L1 Red which connects to L1 on the tester L2 White or yellow which connects to L2 on the tester L3 Blue or black which connects ...

Page 5: ...ght Look at the Leds while doing that It is important to ensure that the user looks from the front side onto the driving shaft and the front side of the tester at the same time so that motor rotation can be confirmed The red LED Right arrow L1 L2 L3 indicated clockwise motor rotation if the lines are connected as follows L1 to U L2 to V L3 to W The red LED Left arrow L1 L2 L3 indicates counter clo...

Page 6: ... the battery voltage is below the threshold the LED will not light up thus replacing the battery indication PREPARATION FOR USE Fuses In doubt check the fuses using a ohm meter Please note that this instrument will not indicate anything should the fuses be blown Test Leads Check the test leads for defects or cracks Replace if cracked or damaged Only replace with the same type Cleaning Clean the in...

Page 7: ...n Over Load 550V between all terminals Frequency Range Class III 600V towards Ground Fuses 5 20 mm 200mA 250V fuse General Battery 9V IEC 6LR61 Current Consumption Max 18 mA Ground MECHANICAL Size 151 72 35 mm Material Poly carbonate ABS Weight less carrying case 120g with batteries Display Neon Lamps and LEDs ENVIRONMENTAL Operating temperature Range 15ºC to 55ºC Storage Temperature 20ºC to 70ºC ...

Page 8: ...horized dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at option free of charge repair or replacement of a defective product which is returned to a KUSAM MECO authorized service center within the warranty period THIS WARRANTY I...

Reviews: