background image

®

®

05

B. LCD Display :

1.

: Battery mark shows current residual battery  power.  Has 
  following 5 grades :
: battery is sufficient.
: battery is comparative sufficient.
: battery is nearly deficient.
: battery is nearly exhausted, need to have a replacement.
: battery is exhausted completely.

2.

LO :

 Low frequency symbol. (10Hz~1kHz)

3. Measured value display.
4.

: Take the maximum value.

MAX

HOLD

E

º

6.

: Temperature unit display, “ºC”  for  the Celsius scale, “ºF” for 
  the Fahrenheit scale.

5. Temperature and maximum value display.

7.

: Value hold.

8.

2

mm/s  :

When    measuring    acceleration,    LCD   will   display

2

acceleration unit “m/s ”.
When measuring velocity, LCD will display velocity unit

2

“mm/s ”.
When    measuring   displacement,   LCD   will   display 
displacement unit “mm”.

9.

1KHz :

 1KHz indication.

10.

HI :

 High frequency symbol. (1kHz~15kHz)

LO

1KHz

HI

MAX

HOLD

2

mm/s

i888

. . .

i888

. . .

E

º

1

3

4

7

5

11

10

9

2

8

6

11.

: Backlight icon, the back light will be active for 7 seconds.

06

V. OPERATING INSTRUCTIONS :

This  vibration  meter  is  designed to fit the different measurement 
requirements as follows :

1.

With  Detector  probe  S  : 

It  provides  good 

response and reproducibility over a wide range.

ON/

MEAS

ON/

MEAS

2.

With Detector head L : 

Suitable for narrow object or

special objects to obtain quick response.

3.

With Magnetic probe : 

Suitable for measurement in

cases  where  flat  Ferric  object  to  the  stable 
measurement.

ON/

MEAS

4.

Without probe tip : 

In this condition, best high-range

response  is  achieved  (10Hz  to  15kHz),  but  planar 
contact with the measurement object is required.

ON/

MEAS

Summary of Contents for KM 63A

Page 1: ...tance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood Paper Grain Moisture Meter Transistorised Electronic Analog Digital Insulation Resistance...

Page 2: ...ON METER MODEL KM 63A TABLE OF CONTENTS TITLE PAGE NO I Before Use II Features III Specifications IV Diagram of the Unit V Operating Instructions VI Maintenance VI Test Certificate VII Warranty 01 02 03 04 06 14 15 16 ...

Page 3: ... the vibration measurement of rotating and reciprocating machinery The unit can measure acceleration velocity and displacement which is widely used in mechanical manufacture electric power metallurgy and general aviation field etc 02 II FEATURES LCD displays measurement result and conditions directly 2 Measures acceleration m s peak velocity mm s ms and displacement mm p p Selective vibration char...

Page 4: ...display full scale Load impedance 10K or more Earphones can be connected 9V battery 15 A 25mA Approx 20H continuous use Turns off automatically after 60 seconds 7 seconds 0 40ºC 30 90 RH 6 4V 0 2V 70 x 30 x 150mm Approx 137g not including battery Technical specification 04 IV DIAGRAM OF THE UNIT 1 2 7 3 4 8 9 5 6 A Instruction of main parts 1 Sub unit handle connector with directionality 2 LCD scr...

Page 5: ...en measuring displacement LCD will display displacement unit mm 9 1KHz 1KHz indication 10 HI High frequency symbol 1kHz 15kHz LO 1KHz HI MAX HOLD 2 mm s i888 i888 E º 1 3 4 7 5 11 10 9 2 8 6 11 Backlight icon the back light will be active for 7 seconds 06 V OPERATING INSTRUCTIONS This vibration meter is designed to fit the different measurement requirements as follows 1 With Detector probe S It pr...

Page 6: ...et C TURN ON THE UNIT AND CHECK UP BATTERY 1 Press the to turn on the main unit or on the handle sub unit key to turn on ON MEAS ON MEAS 2 After the entire screen displays for 1 second the default state is acceleration mode If the LCD displays the symbol or as shown in following figure please promptly replace the battery Low battery indication LO 1KHz 2 m s 000 23 E º D SELECTING MEASUREMENT MODE ...

Page 7: ...ation measure High frequency measuring 1kHz 15kHz Caution High frequency measurement is only for acceleration measure mode 10 F Measurement Depending on the material physical value and vibratory source s vibration frequency select the corresponding measurement mode Acceleration Velocity Displacement and frequency HI LO holding pressed the main unit or sub unit handle s button Press the handle sens...

Page 8: ... S is apply to measure high low frequency range vibration 2 Probe L is only for low frequency measure when measuring acceleration if the frequency is over 1kHz please change to Probe S for measurement 12 3 When switching measurement mode from acceleration in high frequency mode to velocity or displacement mode the unit will change to low frequency automatically 4 Auto power off for 1 minute 5 LCD ...

Page 9: ...e S With probe L Response db 15 10 5 0 5 0 5 10 5 0 5 10 15 20 5K 10K 15K 20K 25K VI MAINTENANCE A Replacement and upkeep of battery 1 After power on if an icon appears on the LCD you need to replace the battery immediately for details please refer figures and contents on page 9 of this manual 2 Remove the battery from the unit if it is not required for extended period of time in order to avoid da...

Page 10: ...hority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at option free of charge repair or replacement of a defective product which is returned to a KUSAM MECO authorized service center within the warranty period THIS WARRANTY IS BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT...