Kusam-meco KM 3060 Operation Manual Download Page 2

®

®

®

AN ISO 9001:2015 COMPANY

MODEL - KM 3060

OPERATION MANUAL

DIGITAL CLAMP MULTIMETER

®

G 17, Bharat Industrial Estate, T. J. Road, 

Sewree (W), Mumbai - 400 015. INDIA. 

Sales Direct :

 (022) 24156638

Tel. :

 (022) 24124540, 24181649. 

Fax :

 (022) 24149659

Email :

 [email protected] 

Website : 

www.kusamelectrical.com

®

LIST OF PRODUCTS

¬

 Digital Multimeter                    

¬

 Digital AC & AC/DC Clampmeter

¬

 AC Clamp Adaptor                  

¬

 AC/DC Current Adaptor

¬

 Thermo Anemometer               

¬

 Thermo Hygrometer

¬

 Distance Meter                        

¬

 Digital Lux Meter

¬

 Network Cable Tester              

¬

 Power Factor Regulator

¬

 Earth Resistance Tester           

¬

 Digital Panel Meters

¬

 DC Power Supplies                 

¬

 High Voltage Detector

¬

 Calibrators                               

¬

 Gas Analysers

¬

 Frequency Counter                  

¬

 Function Generator

¬

 Phasing Sticks                         

¬

 Battery Tester

¬

 Waterproof Pen Testers           

¬

 Solar Power Meter

¬

 EMF Detector

¬

 Wood, Paper & Grain Moisture Meter

¬

 Transistorised Electronic Analog & Digital Insulation   

    Resistance Testers(upto 10 KV)

¬

 Digital Sound Level Meter & Sound Level Calibrator

¬

 Digital contact & Non-contact Type Tachometer

¬

 Digital Non-contact (infrared) Thermometer

¬

 Maximum Demand Controller/Digital Power Meter

¬

 Digital Hand Held Temperature Indicators

Summary of Contents for KM 3060

Page 1: ...New catlog 2015 new arrival catalogs KM 3060 cdr 1000A AC DIGITAL CLAMPMETER ELECTRICAL SPECIFICATIONS KM 3060 AC CURRENT Range Overload Protection 1200A within 60 seconds 20 A 200 A 50Hz 60Hz 1000 A Accuracy Resolution 3 rdg 5dgts 0 01 mA 2 rdg 5dgts 0 1 mA 2 rdg 5dgts for 800A below 3 rdg 5dgts for others current 1 A AC VOLTAGE Range Overload Protection 750V AC DC on all ranges Input Impedance 9...

Page 2: ...er Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood Paper Grain Moisture Meter Transistorised Electronic Analog Digital Insulation Resistance Testers ...

Page 3: ...neglected contaminated or damaged by accident or abnormal conditions of operation or handling KUSAM MECO authorized dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at option free of charge repair or replacement of a defective pr...

Page 4: ...1200A within 60 seconds Jaw opening 2 5cm Instruction Manual This meter is completely portable LCD 31 2 digit clamp meter Designed for use by electricians technicians serviceman It s rugged structure design is good feeling to hold in operator s hand and convenient to use 08 TEST CERTIFICATE This Test Certificate warrantees that the product has been inspected and tested in accordance with the publi...

Page 5: ...or continuity position 3 4 2 Turn off the power from the circuit under test 3 4 3 Connect the red test lead to the VGA jack and the black test lead to the COM jack 3 4 4 Touch the probes to the test points In ohms the value indicated in the display is the measured value of resistance In continuity test the beeper sounds continuously if the resistance is less than 50G 3 5 FREQUENCY Measurement 3 5 ...

Page 6: ...voltage value on Digital Display 3 2 AC Current Measurement 3 2 1 Set Function Range Switch to the ACA 1000A range if the display indicates one or more leading zeros shift to the 200A or 20A range to improve the resolution of the measurements 3 2 3 Press the trigger to open the transformer jaws and clamp one conductor only It is impossible to make measurements when two or three conductors wires ar...

Page 7: ...ty over range and LO BAT indicators 4 Data Hold Switch A push switch Push ON Push OFF do not pull to select function Push ON to hold the measured value and store the value in memory_ Push OFF to release hold function A rotary switch is used to select measurement Function and Range switch 5 Rotary Switch 05 6 connector High input terminal for voltage resistance continuity measurement Accept banana ...