I.SAFETY INFORMATION
● Read the following safety information carefully before
attempting to operate or service the meter.
● To avoid damages to the instrument, do not exceed the
maximum limits of the input values shown in the technical
specification tables.
● Never measure current while the test leads are inserted into
the input jacks.
● Do not use the meter or test leads if they lock damaged. Use
with extreme caution when working around bare conductors
or bus bars.
● Accidental contact with the conductor could result in electric
shock.
● Use the meter only as specified in this manual; otherwise, the
protection provided by the meter may be impaired.
● Read the operating instructions before use and follow all
safety information.
● Be cautious when working with voltages above 60V DC or
30V AC RMS. Such voltages pose a shock hazard.
● Before taking resistance measurements or testing acoustic
continuity. disconnect circuit from main power supply and all
loads from circuit.
II) FEATURES:
■
Measurement CAT II 600V AC/DC
■
Pollution Degree 2
Altitude upto 2000 meters
■
■ Indoor use only
■ Relatively humidity 80% max.
Maintenance & Clearing:
1. Repairs or servicing not covered in this manual should only be
performed by qualified personnel.
2. Periodically wipe the case with a dry cloth. Do not use
abrasives or solvents on this instrument.
Maximum voltage between any terminal and earth ground 750 Vrms
02
GENERAL SPECIFICATIONS:
í
Display :
3-5/6 digits liquid crystal display (LCD)
Max. Rading 5999. Automatic indication of
functions and symbols.
Cables
Φ
36mm
í
J
aw Size :
í
Maximum Voltage between any terminal &
Earth ground 750 Vrms.
í
Operating Temperature :
0~40°C
Operating Principle :
Dual slope integration
í
LCD will show a “OL” in the highest
í
Over Range Indication :
position accompanied. (except for ranges of 1000A AC, and
1000VDC or 750VAC)
The is displayed when the battery
í
Low Battery Indication :
voltage drops below the operating voltage.
2.5times/sec (Digital Display).
í
Sampling rate :
60hrs approx.(Alkaline)
í
Battery Life :
Automatic polarity “-” display for negative input
í
Polarity :
Auto Power Off :
The meter is powered off 15 minutes
í
later after the last operating was made. To bringe back
the display please turn rotary switch to more positions
or push any button
0°C to 40°C (R.H.<80%)
í
Operating Temperature & Humidity :
-
10°C to 60°C (R.H.<80%)
í
Storage Temperature & Humidity :
1.5V AA x 2 Alkaline Battery.
í
Power Supply :
228(L) x 75(W) x 36(H)mm
í
Dimension :
Approx. 465 gms. (including battery).
í
Weight :
ACCESSORIES :
Test leads set, Users Manual, Battery & Carrying Case.