Kusam-meco KM 3060-T Operation Manual Download Page 1

®

®

®

AN ISO 9001:2015 COMPANY

MODEL - KM 3060-T

OPERATION MANUAL

 1000A AC DIGITAL 

CLAMPMETER

®

G 17, Bharat Industrial Estate, T. J. Road, 

Sewree (W), Mumbai - 400 015. INDIA. 

Sales Direct :

 (022) 24156638, 27754546

Tel. :

 (022) 24124540, 24181649, 27750662. 

Email :

  [email protected] 

Website : 

www.kusamelectrical.com

®

LIST OF PRODUCTS

¬

 Digital Multimeter                    

¬

 Digital AC & AC/DC Clampmeter

¬

 AC Clamp Adaptor                  

¬

 AC/DC Current Adaptor

¬

 Thermo Anemometer               

¬

 Thermo Hygrometer

¬

 Distance Meter                        

¬

 Digital Lux Meter

¬

 Network Cable Tester              

¬

 Power Factor Regulator

¬

 Earth Resistance Tester           

¬

 Digital Panel Meters

¬

 DC Power Supplies                 

¬

 High Voltage Detector

¬

 Calibrators                               

¬

 Gas Analysers

¬

 Frequency Counter                  

¬

 Function Generator

¬

 Phasing Sticks                         

¬

 Battery Tester

¬

 Waterproof Pen Testers           

¬

 Solar Power Meter

¬

 EMF Detector

¬

 Wood, Paper & Grain Moisture Meter

¬

 Transistorised Electronic Analog & Digital Insulation   

    Resistance Testers(upto 10 KV)

¬

 Digital Sound Level Meter & Sound Level Calibrator

¬

 Digital contact & Non-contact Type Tachometer

¬

 Digital Non-contact (infrared) Thermometer

¬

 Maximum Demand Controller/Digital Power Meter

¬

 Digital Hand Held Temperature Indicators

Summary of Contents for KM 3060-T

Page 1: ...Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Fun...

Page 2: ...overed in this manual should only be performed by quali ed personnel 2 Periodically wipe the case with a dry cloth Do not use abrasives or solvents on this instrument Maximum voltage between any termi...

Page 3: ...current error is speci ed within the largest circle which can be drawn inside the jaw 2 2 Measurement Speci cations 04 RESISTANCE Range Overload Protection 250V RMS Accuracy Resolution 600 W 1 2 rdg 2...

Page 4: ...on In the backlight on status press the key over 2 seconds the backlight will be o 06 IV OPERATING INSTRUCTION 4 1 Measurement Procedure operating instructions 1 Make sure that the selected range is s...

Page 5: ...shock hazard or damage to the instrument 08 3 Connect the red test to the anode side and black test lead to the cathode side of the diode being tested 4 Read forward voltage Vf value on LCD If the tes...

Page 6: ...is below 50 it will indicate by a continuous beeping NOTE Continuity test is available to check open short of the circuit 10 V MAINTENANCE 5 1 Battery Replacement WARNING To prevent electrical hazard...

Page 7: ...patch of goods In case any defect occurs in functioning of the instrument under proper use within the warranty period the same will be rectified by us free of charges provided the to and fro freight c...