Kusam-meco KM 2775 Operation Manual Download Page 1

An ISO 9001:2008  Company

®

G-17, Bharat  Industrial  Estate,  T. J.  Road,  Sewree (W),  Mumbai -  400 015. INDIA.

Sales Direct.:

 022 -24156638,     

Tel. : 

022-24124540, 24181649,      

Fax : 

022 - 24149659

Email :

 [email protected],                                        

Website :

 www.kusamelectrical.com

An ISO 9001:2008  Company

®

All Specifications are subject to change without prior notice

D:\Chhaya\My Documents\Chhaya\backup\catlogs\NEW CAT\2013-14\KM 2775 revised 28 march 15.cdr

11 FUNCTIONS  34 RANGES

Model  KM 2775

CA

T III 600V

CE 

Approved

SAFETY :

?

  

Withstand Voltage : 

6000V

?

  

IEC/EN61010-1 EN61010-2-32  CAT III 600V

SPECIAL FEATURES :

?

   Auto Ranging

?

   Full Automatic measurement

?

   Range change function

?

   Data Hold function freezes the reading

?

   Continuity & Diode Measurements

?

   Auto Power Off

?

   Low Battery Indication

GENERAL SPECIFICATIONS :

í

 

Sensing :

 Average Sensing.

í

 

Jaw opening size :

 55mm Max.

í

 

Display : 

 3¾ digits 4000 counts LCD display   

í

 

Sample Rate :

 Approx. 2 times per second

í

 

Response Time :

 Approx. 1 second

í

 

Low Battery :

 “      ” sign appears on the display  when the battery Voltage drops below accurate 

     operating level.

í

 

Over range indication :

 “O.L” indicated

í

 

Operating Principle : 

Dual slope integration

í

 

Storage Temperature : 

-20°C

 

 to 60°C, <80% R.H.    

í

 

Temperature & Humidity for Guaranteed accuracy @ -10°C to 50°C at <80% R.H.

í

 

Power Supply :

 Standard 9V battery

       

í

 

Dimension :

 260(L) X 95(W) X 43(D) mm

í

 

Weight : 

Approx. 515

 

gm (battery included)

ACCESSORIES :

 

Test leads, Carrying Case, Battery installed,  

User's  Manual.

ELECTRICAL  SPECIFICATIONS  - KM 2775

Accuracy is ± (% reading number of digits ) or otherwise specified, at 23°C ± 5°C & less than equal to 80% R.H. 

DC CURRENT

400   A

2000 A

Range

±(1.5%rdg + 4dgts)

Resolution

Accuracy

0.1        A

1           A

±(1.5%rdg + 4dgts)

RESISTANCE

400    

W

4      K

W

40    K

W

400  K

W

4      M

W

40    M

W

Range

Resolution

0.1     

W

1        

W

10      

W

100    

W

1      K

W

10    K

W

±(1.5%rdg + 3dgts)

Accuracy

±(1.5%rdg + 3dgts)

±(2.0%rdg + 4dgts)

±(1.5%rdg + 3dgts)

±(1.5%rdg + 3dgts)

±(1.5%rdg + 3dgts)

Overload Protection : 

 500V AC rms or 500V DC

FREQUENCY

4     KHz

20   KHz

Range

Resolution

1        Hz

10      Hz

Accuracy

±(0.3%rdg + 2dgts)

±(0.3%rdg + 2dgts)

Overload Protection :  

500V AC rms or 500V DC

Trigger level : 

0.2V

AC VOLTAGE

Range

Resolution

Accuracy

400 mV

4        V

40      V

400    V

600  V

0.1        mV

1           mV

10         mV

100       mV

1              V

±(2.0%rdg + 3dgts)

±(1.5%rdg + 3dgts)

±(1.5%rdg + 3dgts)

±(1.5%rdg + 3dgts)

±(1.5%rdg + 3dgts)

Overload Protection   : 

600V AC RMS

Frequency Response :

 0 ~ 400mV at 40Hz ~ 100Hz

                                        4V ~ 600V at 40Hz ~ 500Hz

DC VOLTAGE

400 mV

4        V

40      V

400    V

600  V

Range

Resolution

0.1        mV

1           mV

10         mV

100       mV

1              V

±(1.0%rdg + 3dgts)

Accuracy

±(1.0%rdg + 3dgts)

±(1.0%rdg + 3dgts)

±(1.0%rdg + 3dgts)

±(1.0%rdg + 3dgts)

Overload Protection   : 

600V AC RMS

Frequency Response   : 

40Hz ~ 1kHz

AC CURRENT

400   A

2000 A

Range

±(2.0%rdg + 4dgts)

Resolution

Accuracy

0.1        A

1           A

±(2.0%rdg + 4dgts)

Overload Protection : 

500V AC rms or 500V DC

CONTINUITY TEST

400   

W

Range

Audible Threshold

Less than 25

W

DIODE TEST

2       V

Range

Resolution

±(1.5%rdg + 3dgts)

Accuracy

1        mV

CAPACITANCE

4      nF

(30p~4nF)

40    nF

400  nF

4      

m

F

40     F

m

400   F

m

4      mF

Range

Resolution

1           pF

10         pF

100       pF

1           nF

10         nF

100       nF

1            F

m

Overload Protection :  

500V AC rms or 500V DC

±(3.0%rdg + 5dgts)

Accuracy

±(2.0%rdg + 5dgts)

±(2.0%rdg + 5dgts)

±(2.0%rdg + 5dgts)

±(2.5%rdg + 5dgts)

±(2.5%rdg + 5dgts)

±(2.5%rdg + 5dgts)

3¾ DIGIT 2000A AC/DC 

DIGITAL CLAMPMETER

WARNING

Please do not change to any other DCV or Ohm range when you are 
inputing 600V AC/DC.  Make sure that you have turned off the input 
voltage and then you can change to another range for testing.

Summary of Contents for KM 2775

Page 1: ... 80 R H DC CURRENT 400 A 2000 A Range 1 5 rdg 4dgts Resolution Accuracy 0 1 A 1 A 1 5 rdg 4dgts RESISTANCE 400 W 4 KW 40 KW 400 KW 4 MW 40 MW Range Resolution 0 1 W 1 W 10 W 100 W 1 KW 10 KW 1 5 rdg 3dgts Accuracy 1 5 rdg 3dgts 2 0 rdg 4dgts 1 5 rdg 3dgts 1 5 rdg 3dgts 1 5 rdg 3dgts Overload Protection 500V AC rms or 500V DC FREQUENCY 4 KHz 20 KHz Range Resolution 1 Hz 10 Hz Accuracy 0 3 rdg 2dgts...

Page 2: ...ised Electronic Analog Digital Insulation Resistance Testers Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared Thermometer Thermo Hygrometer Thermo Anemometer Wood Moisture Meter Distance Meter Digital Hand Held Temperature Indicators Digital Lux Meter Network Cable Tester Power Factor Regulator Maximum Demand Controller Digit...

Page 3: ...ter Don t try to measure current in excess of your meter s capacity Check the current capacity of the Clamp meter If you are measuring current in industrial environment to prevent excess current from flowing through your meter always disconnect your test leads from the circuit under test whenever you change Clamp meter functions Set your meter to the correct function say current and its highest ra...

Page 4: ...e inpaired Always keep hands behind the meter barrier Use extreme caution when clamping around uninstalled conductors or bus bars Never clamp around any conductor carrying a voltage above 600V R M S Rated environmental conditions 1 Indoor use 2 Installation category III 3 Pollution degree II 4 Altitude up to 2000 meter 5 Relative humidity 80 max o 6 Ambient temperature 0 40 C Observe the internati...

Page 5: ...g Continuity check Diode measurement Low battery indication Auto Power Off APO function Safety design throughout with no exposed metal parts shielded banana plugs and recessed input terminals 4 GENERAL Overload Protection ACV 600V rms DCV 600V Frequency Ohm 500V rms Conductor Size Approx 55mm max Dimensions 260mm L X 95mm W x 43mm D Weight Approx 540g Battery included Power Source Standared 9V Bat...

Page 6: ...0 V 600 V 0 1 mV 1 mV 10 mV 100 mV 1 V 2 0 rdg 3dgt 1 5 rdg 3dgt 1 5 rdg 3dgt 1 5 rdg 3dgt 1 5 rdg 3dgt Overload Protection 600V AC RMS Frequency Response 0 400mV at 40Hz 100Hz 4V 600V at 40Hz 500Hz DC Voltage Range Resolution Accuracy at 40 500Hz 400 mV 4 V 40 V 400 V 600 V 0 1 mV 1 mV 10 mV 100 mV 1 V 1 0 rdg 3dgt 1 0 rdg 3dgt 1 0 rdg 3dgt 1 0 rdg 3dgt 1 0 rdg 3dgt Overload Protection 600V DC AC...

Page 7: ... threshold 400 W Less than 25W Overload Protection 500V AC RMS or 500V DC Diode Test Range 2V Resolution Accuracy 1 mV 1 5 rdg 3dgt 7 8 Capacitor Range Resolution Accuracy 4 nF 30p 4nF 1 pF 10 pF 100 pF 1 nF 10 nF 100 nF 1 mF 3 0 rdg 5dgt 2 0 rdg 5dgt 2 0 rdg 5dgt 2 0 rdg 5dgt 2 5 rdg 5dgt 2 5 rdg 5dgt 2 5 rdg 5dgt Overload Protection 500V AC RMS or 500V DC 40 nF 400 nF 4 mF 40 mF 400 mF 4 mF Freq...

Page 8: ...ective distance from hands to conductor 3 Jaw Trigger Press the lever to open the transformer jaws When the lever is released the jaws will close again 4 Function selector rotary switch The rotary switch selects the function 5 LCD Display The LCD display indicates the function mode bar graph annunciator and measured value of a signal Field effects 3 digit LCD with maximum reading of 3999 OFF 600V ...

Page 9: ...s resistance Continuity or diode function 9 Range Button Press the Range button to selects the manual range mode and turns off the AUTO annunciator and turns on the manual annunciator and changes the full scale range In manual range mode each time press Range button less than one second the range increments and a new value is displayed To exit the manual range mode and return to auto mode press th...

Page 10: ...directly 3 Resistance Measurement 13 Continuity check shares the same configuration with 400 0W manual resistance measurement mode but with buzzer output to indicate continuity The buzzer generates a 2KHz sound whenever the digit number less than 25W Because the cycle time of measurement is only 50ms the least significant digit will not display 4 Continuity Check Diode measurement mode shares the ...

Page 11: ...5 16 When low battery warning appears chance a new battery as follows 1 Disconnect the test leads from the instrument and turn off power 2 Unscrew the battery cover and replace a new battery 8 MAINTENANCE Battery Replacement Cleaning and Storage WARNING To avoid electrical shock or damage to the meter do not get water inside the case Periodically wipe the case with a damp cloth and detergent Do no...

Page 12: ...orized dealer This warranty does not apply for damaged Ic s fuses burnt pcb s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered neglected contaminated or damaged by accident or abnormal conditions of operation or handling KUSAM MECO authorized dealer shall extend this warranty on new and unused products to end user customers only...

Reviews: