09
AutoV_ACV
AutoV_ACV
Range
Range
45Hz ~ 440Hz
45Hz ~ 440Hz
600.0V
600.0V
Accuracy
Accuracy
¹
±(2%rdg+3dgts)
±(2%rdg+3dgts)
1000V
1000V
Resolution
Resolution
100 mV
100 mV
1 V
1 V
1)Not specified at <1VAC
Threshold: > 1VAC nominal
Approximate input impedance (//164pF) for reference:
At direct input 50Vac (typical) from quiescence:
>8M
Ω
@ < 5.6Vac
22k
Ω
@ 7Vac
12k
Ω
@ 8Vac
2.6k
Ω
@ 50Vac
At direct input >>50V (typical) from quiescence:
Initial impedance is approximately 2.3k
Ω
. Impedance increases
abruptly within a fraction of a second as display voltage
(hard signal) is much higher than 50V
(typical). End-up impedances vs display voltages typically are:
12k
Ω
@100V
100k
Ω
@300V
240k
Ω
@600V
580k
Ω
@1000V
AutoV_DCV
Range
600.0V
Accuracy
¹
±(2%rdg+3dgts)
1000V
Resolution
100 mV
1 V
1)Not specified at <1VDC
Threshold: > +1.0VDC or < -1.0VDC nominal
Approximate input impedance (//164pF) for reference:
At direct input < 50Vdc (typical) from quiescence:
10
AC Current
Range
Burden Voltage
Accuracy
600.0
m
A
6000
m
A
60.00mA
600.0mA
1)
6.000A
2)
10.00A
0.1mV/
m
A
1.9mV/mA
0.04V/A
1.5% + 3d
1.0% + 3d
Resolution
1) <5d non-zero residue may appear when backlight is on, which
will not affect the specified measuring range and accuracy
2) 10A continuous, >10A to 20A for 30 seconds max with 5 minutes
cool down interval
50HZ ~ 400HZ
100 nA
1
m
A
10
m
A
100
m
A
1 mA
10 mA
>8M
Ω
@ < 8Vdc (Protection clamping threshold)
25k
Ω
@ 9Vdc
13k
Ω
@ 10Vdc
2.6k
Ω
@ 50Vdc
At direct input >>50V (typical) from quiescence:
Initial impedance is approximately 2.3k
Ω
. Impedance increases
abruptly within a fraction of a second as display voltage
(hard signal) is much higher than 50V\ (typical). End-up impedances
vs display voltages typically are:
12k
Ω
@100V
100k
Ω
@300V
240k
Ω
@600V
580k
Ω
@1000V
±(0.9%rdg+2d)
Diode Tester
Range
Accuracy
3.000V
Test Current :
0.3mA typical
Open Circuit Voltage :
< 3.2VDC typical
Resolution
100 mV