Kusam-meco KM 181 Operation Manual Download Page 1

LIST OF PRODUCTS

OPERATION

MANUAL

DIGITAL CLAMPMETER

+ MULTIMETER

KM 181

*  

Digital Multimeter                    

*  

Digital AC & AC/DC Clampmeter

*  

AC Clamp Adaptor                  

*  

AC/DC Current Adaptor

*  

Thermo Anemometer               

*  

Thermo Hygrometer

*  

Distance Meter                        

*  

Digital Lux Meter

*  

Network Cable Tester              

*  

Power Factor Regulator

*  

Earth Resistance Tester           

*  

Digital Panel Meters

*  

DC Power Supplies                 

*  

High Voltage Detector

*  

Calibrators                               

*  

Gas Analysers

*  

Frequency Counter                  

*  

Function Generator

*  

Phasing Sticks                       

*  

Battery Tester

*  

Waterproof Pen Testers           

*  

Solar Power Meter

*  

EMF Detector

*  

Wood, Paper & Grain Moisture Meter

*  

Transistorised Electronic Analog & Digital 

    Insulation  Resistance Testers(upto 10 KV)

*  

Digital Sound Level Meter & Sound Level 

    Calibrator

*  

Digital contact & Non-contact Type Tachometer

*  

Digital Non-contact (infrared) Thermometer

*  

Maximum Demand Controller/Digital Power 

    Meter

*  

Digital Hand Held Temperature Indicators

®

Summary of Contents for KM 181

Page 1: ...Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood Paper Grain...

Page 2: ...ter becomes a low impedance circuit element Even if you correctly insert your clamp meter in to the circuit you can still damage your meter Don t try to measure current in excess of your meter s capac...

Page 3: ...r IEC61010 1 2nd Ed EN61010 1 2nd Ed UL61010 1 2nd Ed CAN CSA C22 2 No 61010 1 0 92 IEC61010 2 032 EN61010 2 032 UL61010B 2 032 CAN CSA C22 2 No 61010 2 032 04 Measurement Category III 600V AC DC Per...

Page 4: ...mine proper meter functioning Keep your hands fingers behind the hand finger barriers of the meter and the test leads that indicate the limits of safe access of the hand held part during measurement I...

Page 5: ...6 digits 6000 counts 3 1 2 digits 1 999 counts for Hz Polarity Automatic Update Rate 5 per second nominal Operating Temperature 0 C to 40 C Pollution degree 2 Altitude Operating below 2000m Relative...

Page 6: ...y 100 digits Performance above 3V m is not specified 7 KUSAM MECO April 2011 6 ELECTRICAL SPECIFICATIONS Accuracy is reading digits number of digits or otherwise specified at 23 C 5 C less than 75 rel...

Page 7: ...00W 32ms approx Audible Threshold Response Time 9 KUSAM MECO April 2011 AutoCheck_ACV with Low Pass Filter Range Resolution Accuracy1 6 000V 60 00V 3 0 rdg 80 dgts 600 0V 2 600V 1 mV 10 mV 100 mV 1 V...

Page 8: ...Add 12d to specified accuracy while reading is at 1 to 10 of range 2 Induced error from adjacent current carrying conductor 0 5A A 3 Specified accuracy is from 1 to 100 of range and for measurements m...

Page 9: ...s for non invasive current measurements Hz ACA function 12 KUSAM MECO April 2011 7 PRODUCT DESCRIPTION CREST C HOLD H EF REL PC Comm VFD RANGE Hz Hz VFD Auto VW 0 000V 1 2 3 3 4 5 7 8 9 10 6 1 Transfo...

Page 10: ...asurement Locate the conductor s at the Jaws center as much as possible to get the best measuring accuracy For removal press the jaw trigger and remove the jaws from the conductor s CAUTION Applicatio...

Page 11: ...heck mode an unexpected display of voltage readings alerts you that the object under test is being energized 17 KUSAM MECO April 2011 Ghost Voltage Buster Gost Voltages are unwanted stray signals coup...

Page 12: ...VW 2 008k W CREST C HOLD H EF REL PC Comm VFD RANGE Hz Hz VFD Auto VW 1 2W 00 18 KUSAM MECO April 2011 CREST C HOLD H EF REL PC Comm VFD RANGE Hz Hz VFD Auto VW Auto VW LoZ LoZ CREST C HOLD H EF REL...

Page 13: ...in sequence Note Hz Hz Both ACV LoZ VFD ACV LoZ function selection are equipped with low pass filter to deal with VFD Variable Frequency Device Hz signals VFD ACV LoZ selection however further pre se...

Page 14: ...f are disabled automatically in this mode Hold The hold feature freezes the display for later view Press the HOLD button momentarily to toggle the hold feature Relative Zero mode r Relative Zero mode...

Page 15: ...ain meter accuracy If self diagnostic massage C_Er is being displayed while powering on some meter ranges might be largely out of specifications 24 KUSAM MECO April 2011 Manual or Auto ranging Note Ma...

Page 16: ...01 REGISTERED QC PASS KUSAM MECO 26 KUSAM MECO April 2011 To avoid mis leading measurements stop using the meter and send it for re calibration Cleaning and Storage Periodically wipe the case with a d...

Page 17: ...ed dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO G 17 Bharat Industria...