2006/95/EC and Electromagnetic compatibility directive 2004/108/EC

-4-

Average sensing (KM 061)
True RMS sensing (KM 062)

Safety                                 :   

Meets IEC61010-1 2nd Ed., EN61010-1

                                               2nd Ed., UL61010-1 2nd Ed., CAN/CSA

                                               C22.2 No. 61010.1-0.92, IEC61010-2-032, 

                                               EN61010-2-032 & UL61010B-2-032 & 

                                               CAN/CSA C22.2 No. 61010-2-032-04:

                                               Category III 600 Volts AC & DC.

Transient Protection         :   

6.5kV (1.2/50

m

S surge) 

Pollution degree               :  

 2

Summary of Contents for KM 061

Page 1: ...Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Tester...

Page 2: ...e current in excess of your meter s capacity Check the current capacity of the Clamp meter If you are measuring current in industrial environment to prevent excess current from flowing through your me...

Page 3: ...sers is double insulation per IEC61010 1 2nd Ed EN61010 1 2nd Ed UL61010 1 2nd Ed CAN CSA C22 2 No 61010 1 2nd Ed IEC61010 2 032 EN61010 2 032 UL61010B 2 032 CAN CSA C22 2 N0 61010 2 032 04 Category C...

Page 4: ...M 061 True RMS sensing KM 062 Safety Meets IEC61010 1 2nd Ed EN61010 1 2nd Ed UL61010 1 2nd Ed CAN CSA C22 2 No 61010 1 0 92 IEC61010 2 032 EN61010 2 032 UL61010B 2 032 CAN CSA C22 2 No 61010 2 032 04...

Page 5: ...10m A KM 061 190m A KM062 Dimension 188 L x 63 W x 40 H mm Weight 218gm approx Jaw opening Conductor diameter 30mm max Accessories Test lead pair batteries installed User s Manual Carrying case 6 DC...

Page 6: ...Accuracy decreases gradually to 12 at low battery warning voltage of approx 2 4V 100 mW 1 W 10 W 100 W 1 KW 10 KW 100 pF 1 nF 10 nF 100 nF 1 m F 8 DCA Current Clamp on Range Resolution 1 2 Accuracy 40...

Page 7: ...urrent magnetic field pick up 2 Hand Finger Barrier to indicate the limits of safe access of the meter during measurement 3 Push buttons for special functions features 4 Input jack for all functions E...

Page 8: ...by the selected function range from where the Hz function is activated In ACV function activating the Hz function during significant measurements can get the most appropriate trigger level to avoid e...

Page 9: ...he jaw mark indicates current flow direction on DCA positive readings For removal press the jaw trigger and remove the jaws from the conductor s Inputs are made through the clamp jaws for non invasive...

Page 10: ...ed maximum value as fast as 30ms with auto ranging capability It allows the meter to capture INRUSH currents in current functions Press and hold the MAX button for 1 second or more to toggle to the ma...

Page 11: ...tandard 1 5V AAA size battery x 2 or 1 5V AAA size Alkaline battery x 2 Loosen the 2 captive screws from the battery cover case Lift the battery cover case Replace the batteries Replace battery cover...

Page 12: ...CO authorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused alte...