Kusam-meco 207-MK-1 User Manual Download Page 16

ISO 9001

REGISTERED

MUMBAI

TEST CERTIFICATE

DIGITAL MULTIMETER

This  Test  Certificate  warrantees  that 

the  product  has  been  inspected  and 

tested in accordance with the published 

specifications.

The instrument  has been  calibrated by 

using  equipment  which  has  already 

been  calibrated  to  standards  traceable 

to national standards.

MODEL NO. ______________

207 MK-1(T)

SERIAL NO. ___________

DATE: ___________

QC

PASS

KUSAM-MECO

27

28

Each “KUSAM-MECO” product is warranted to be free from 

defects in material and workmanship under normal use & 

service.   The warranty period is one year (12 months) and 

begins from the date of despatch of goods.   In case any 

defect occurs in functioning of the instrument, under proper 

use, within the warranty period, the same will be rectified by 

us free of charges, provided the to and fro freight charges 

are borne by you.
This warranty extends only to the original buyer or end-user 

customer of a “KUSAM-MECO” authorized dealer.
This warranty does not apply for damaged Ic’s, fuses, burnt 

PCB's, disposable batteries, carrying case, test leads, or to 

any product which in “KUSAM-MECO’s” opinion, has been 

misused, altered, neglected, contaminated or damaged by 

accident or abnormal conditions of operation or handling.
“KUSAM-MECO”  authorized  dealer  shall  extend  this 

warranty  on  new  and  unused  products  to  end-user 

customers only but have no authority to extend a greater or 

different warranty on behalf of “KUSAM-MECO”.
“KUSAM-MECO’s” warranty obligation is limited, at option, 

free of charge repair, or replacement of a defective product 

which is returned to a “KUSAM-MECO” authorized service 

center within the warranty period.
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE 

REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, 

EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED 

TO ANY  IMPLIED  WARRANTY  OF  MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE.  “KUSAM-

MECO”  SHALL  NOT  BE  LIABLE  FOR  ANY  SPECIAL, 

INDIRECT,  INCIDENTAL  OR  CONSEQUENTIAL 

DAMAGES  OR  LOSSES,  INCLUDING  LOSS  OF  DATA, 

ARISING FROM ANY CAUSE WHATSOEVER.
All transaction are subject to Mumbai Jurisdiction.

WARRANTY

Summary of Contents for 207-MK-1

Page 1: ...ontact infrared Thermometer Thermo Hygrometer Thermo Anemometer Wood Moisture Meter Distance Meter Calibrators Gas Analysers Panel meters Battery Testers Digital Hand Held Temperature Indicators Digit...

Page 2: ...vironment you can easily exceed those ratings The best way to avoid damage is to use a clamp meter or to connect a clamp attachment to your DMM To prevent excess current from flowing through your mete...

Page 3: ...nging Digital Multimeter Model 207 MK1 T hereafter referred to as the Meter is a 3 digits Multimeter with steady operations and highly reliable hand held measuring instrument having different measurem...

Page 4: ...1 A m Range 400 A m 4000 m A 40 mA 400 mA AC 2 5 rdg 5dgts 0 01 A 10 A 4 GENERAL SPECIFICATIONS Display 3 digit LCD Maximum reading 3999 with automatic sign and function annunciators Overrange Highes...

Page 5: ...1 C Accuracy 0 1 rdg 4dgts Resolution 0 01 Hz Range 9 999 Hz FREQUENCY 0 001 MHz 9 999 MHz Overload Protection 250 V Rms Sensitivity 0 7V Rms 6 DC CURRENT Accuracy 1 2 rdg 2dgts AC 2 rgd 3dgts DC 1 5...

Page 6: ...o the following rules n Before using the Meter inspect the case Do not use the Meter if it is damaged or the case or part of the case is removed Look for cracks or missing plastic Pay attention to the...

Page 7: ...nal button operations 10 V W CAP NPN PNP C m A mA 10A CE OFF OFF Hz SELECT RANGE HOLD Hz DUTY hFE FUSED 10A 15SEC MAX 400mA 1000V MAX VW mA COM 10A 207 MK 1 T 399 9 E E B C The Multimeter Structure se...

Page 8: ...display is not on otherwise false readings may be provided n Pay extra attention to the symbol which is located besides the input terminals of the Meter before carrying out measurement A DC VOLTAGE ME...

Page 9: ...uit voltage between terminals and ground is greater than 60V DC or 30V rms If the fuse burns out during measurement the Meter may be damaged or the operator himself may be hurt 14 Caution n If the val...

Page 10: ...ion and range for the measurement When the testing leads are connected to the current terminals do not parallel them across any circuit The AC current measurement has 5 measurement positions on the ro...

Page 11: ...range for the measurement When the testing leads are connected to the current terminals do not parallel them across any circuit The DC current measurement has 5 measurement positions on the rotary sw...

Page 12: ...10A 15SEC MAX 400mA 1000V MAX V mA W COM 10A 207 MK 1 T 399 9 E E B C Capacitor 20 Note n The test leads can add 0 1W to 0 3W of error to the Resistance measurement To obtain precision readings in lo...

Page 13: ...DUTY hFE FUSED 10A 15SEC MAX 400mA 1000V MAX V mA W COM 10A 207 MK 1 T 399 9 E E B C 22 Caution n Never connect high voltage to the input sockets with the switch in Capacitance range n Using Capacitan...

Page 14: ...value Figure 11 Red Black V W CAP NPN PNP C m A mA 10A CE OFF OFF Hz SELECT RANGE HOLD Hz DUTY hFE FUSED 10A 15SEC MAX 400mA 1000V MAX V mA W COM 10A 207 MK 1 T 399 9 E E B C 24 The frequency measure...

Page 15: ...ads and the circuit under test Testing for Continuity To test for continuity connect the Meter as below 1 Insert the red test lead into VW terminal and the black test lead into the COM terminal 2 Set...

Page 16: ...thorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered n...

Reviews: