Insert / replace  battery

Open the battery compartment using the four 

captive screws. Make sure the polarity is correct 

when inserting the battery. Use only good quality 

batteries.
The TP09D is waterproof. Only the battery com-

partment and the test cord connection area are 

not protected. If water has penetrated into the 

TP09D, this area must be dried.

The TP09D is supplied with a 

sturdy, exchangeable hook for 

mounting, the position of which 

can be changed. If the hook is 

to be removed completely, a 

cover cap for the receptacle is 

included.

9 V Alkaline Battery

Summary of Contents for TP09D

Page 1: ...cts only with written permission of Kurth Electronic GmbH All trademarks and logos mentioned herein belong to their registered owners TP09D Analogue Test Telephone User guide Kurth Electronic GmbH Mue...

Page 2: ...and function keys Removable hook Control buttons Up Down Control buttons Right Left On Off Alphanumeric keypad Battery compartment lid Speaker mode Volume Volume Select button SEL LCD monitor with ba...

Page 3: ...ing for monitor and tele phony and calling Main functions RING TP09D switched off Default setting is on hook Waiting for incoming call with or without CLIP information TALK TP09D switched on Pressing...

Page 4: ...itted information is displayed and stored un der CID RCL The last three calls are stored in the CID RCL memory If no CLIP is trans mitted the information NO CLIP DETECTED If the information is transmi...

Page 5: ...position counter for charge pulse 47 mA Current line current depen ding on the terminal device at LLC Battery Display of battery capacity 5 V Display of polarity or and three digit display of line vo...

Page 6: ...imit errors in telephone systems as easily as possible the flash time the three most important times are adjustable via the Flash times option in the menu is set to a direct key The pause can be inser...

Page 7: ...disturbances during normal conversations or calls ON OFF Advanced funtions For further functions the TP09D is switched on using the red ON OFF key keep the key pressed for more than one second The fol...

Page 8: ...2 Tone 2 Pulse mode 1 10 pps 33 66 2 40 pps 40 60 3 CID mode 1 V23 DT AS 4 SMS options 1 SMS center 1 Number 2 Display SMS text 1 On 2 Off 3 Exit 5 Meter pulse 1 12 kHz 2 16 kHz 6 Line test mode 1 Off...

Page 9: ...andset or the loudspe aker This makes it easy to limit disturbances such as earth voltage noise etc or to determine that the line is occupied The open listening mode is activated with the SPKR On Off...

Page 10: ...tem NOSMS must be selected in the menu If the settings are correct the display shows the sequence of the SMS transmission and if the transmission was successful SMS OK as the result All parameters as...

Page 11: ...ge is shown in the display The MWI status ON or OFF is also displayed CIDCW Option depending on network operator If another call arrives during a call Caller ID Call Waiting its call number is shown i...

Page 12: ...sec and Flash both also multiple times can be inserted and saved Press F2 STO to save Dialling from the speed dial memory The line is assigned the TALK key LNR Re dialling the last three outgoing numb...

Page 13: ...s displayed without sign in monitor and talk mode In this case the negative pole is on the A wire and the positive pole on the B wire The black test cord is intended for connection to earth but is as...

Page 14: ...captive screws Make sure the polarity is correct when inserting the battery Use only good quality batteries The TP09D is waterproof Only the battery com partment and the test cord connection area are...

Page 15: ...10 indirect memory locations with 24 digits each Monitor Impedanz 120 kOhm bei 100 kHz 500 kOhm bei 4 kHz General device data Power supply 9 V Alkaline Battery Display Graphical display Housing Stabl...

Page 16: ...t was not intended can lead to incorrect measure ments and may damage the device The relevant safety regulations in VDE 0100 0800 and 0805 must be adhered to The usage of connections other than those...

Reviews: