"Network" is displayed at the top position. Press SEL to show general
network information such as the connection speed, the actual IP address
and netmask. Press the ▼ button to go to the next page. The following is
displayed:
Domain name of the network
IP address of the DNS server
IP of the DHCP server
IP of the router
Press SEL to save these data.
Press ESC to open the user list. When a user is selected, the IP and
MAC address are displayed in addition to the name. This address can
then be pinged in this menu.
Select SEL to open the PING menu. The range is displayed in the top left
corner. This can be changed
from 32 to 124 bytes with the ▲ / ▼
buttons.
Start pinging by pressing SEL.
The
KE7200
continuously transmits pings to the selected address. This is
done at the maximum speed so that a stress test is simultaneously
performed for all components.
The success of the test is displayed by the number of sent pings and the
number of lost pings. Then the maximum, minimum and average
response times are displayed.
Transmit measurements -
KE7200 only
The saved measurements can be sent to the KE Manager for further use.
Start the Manager on the PC.
Connect the
KE7200
to the PC using an Ethernet cable. In the main
menu, select "
Transmit measurements
."
The saved data are transmitted immediately after synchronization and
appear in the Manager window. The
KE7200
can now be disconnected
from the network.
If there are no saved measurements, this is reported.
The data on the
KE7200
can be deleted. If they should not be deleted,
press ESC.