Loop Analysis
The loop analysis permits automatic measuring sequences which can be selected by the user.
Configuration
The user configures the loop analysis by activating or deactivating entries in a table by pressing
SEL
that
describes a given sequence containing all the measurements and options.
1. Command 'Port 1 connected to Port 2' to KE900 (if not
activated, the instruction
'Connect CO'
appears in the
dialog window)*
2. Current measurement CO(A-B, A-GND, B-GND, AC & DC
in each case)
3. Voltage measurement CO (A-B, A-GND, B-GND, AC & DC
in each case)
4. Command 'All ports open' to KE900 (if not activated,
the instruction
'Disconnect CO'
appears in the dialog
window)*
5. Current measurement (A-B, A-GND, B-GND, AC & DC in
each case)
6. Voltage measurement (A-B, A-GND, B-GND AC & DC in
each case)
7. Command 'Port 1 short-circuited' to KE900 (if not
activated, the instruction 'Close loop' appears in the dialog
window)*
8. Resistance measurement (only A-B)
9. Command 'All ports open' to KE900 (if not activated, the
instruction 'Open loop' appears in the dialog window)*
10. Capacitance measurement (A-B, A-GND, B-GND)
11. Insulation resistance measurement (A-B, A-GND, B-GND)
*If a command to the KE900 is not activated, a dialog window appears
at the corresponding location with the described message and an
associated tone (three short beeps) when the loop analysis is
performed. Exit the dialog by pressing '
ESC
' which reinitiates the
measuring sequence, or you can press '
SEL
' to manually trigger the
unactivated command to the KE900.
Measuring Procedure
You can leave this page by pressing
ESC
which terminates the
loop analysis. Press
F2
(Load) to load a previously saved
configuration, and press
F3
(Save) to save the current
configuration. Press
F4
(Start) to start the loop analysis.
When the loop analysis starts, the results page is displayed
containing a results table of the measurements which are filled
in as the loop analysis progresses.
Dialog windows generated by the configured process may
appear over the results table. These are confirmed by the user
by pressing
ESC
or
SEL
.
After the configured loop analysis is finished, you can restart it
by pressing
F3
(Start), or press
F4
(Save) to open a dialog for
saving the measurements for further processing in the KE-
Manager.
Press
F2
(Conf.) to return to the configuration page.
Press
ESC
to go from the results page to the Digital Multimeter menu.
Operating Manual
KE3600
xDSL
M
ULTI
T
EST
28
KURTH ELECTRONIC www.kurthelectronic.de [email protected]
Help
Date / Time
Loop Analysis Configuration
a/b: 0,0 V
Port 1+2
1
Current
2
Load
Save
Start
Voltage
3
Resistance
8
All Ports Open
4
All Ports Open
9
Current
5
Capacitance
0
Voltage
6
Insulation
Port 1 shorted
7
Help
Date / Time
Loop Analysis Result
a/b: 0,0 V
Conf.
Save
Start
A-B
A-Gnd
B-Gnd
I= CO
0,0 mA
0,0 mA
0,0 mA
I~ CO
1,1 mA
0,9 mA
0,9 mA
U= CO
0,000 V
0,000 V
0,000 V
U~ CO
0,045 V
0,045 V
0,046 V
I=
0,0 mA
0,0 mA
0,0 mA
I~
1,1 mA
0,9 mA
0,9 mA
U~
0,000 V
0,000 V
0,000 V
U~
0,045 V
0,045 V
0,045 V
abc
"
123
Date / Time
Loop Analysis Result
a/b: 0,0 V
Clr
!
Del
A-B
A-Gnd
B-Gnd
I= CO
0,0 mA
0,0 mA
0,0 mA
I~ CO
1,1 mA
0,9 mA
0,9 mA
U= CO
0,000 V
0,000 V
0,000 V
U~ CO
0,045 V
0,045 V
0,046 V
I=
0,0 mA
0,0 mA
0,0 mA
I~
1,1 mA
0,9 mA
0,9 mA
U~
0,000 V
0,000 V
0,000 V
U~
0,045 V
0,045 V
0,045 V
Close Loop
Sel (KE900)
Esc (Continue)
Save Result