background image

CCTS-03

CCTS-03

Shield / metallic sleeve

1

2

3

1

2

3

CABLE

Free double wire

Wire under test

SET A

SET B

To find earth faults, the screen or cable sheath

must be earthed. The red test lead must then be

additionally

 connected to earth on the

transmitter side (TX).

ATTENTION! 

Do not use this connection for tests

on connected copper pairs!

A

B

1

1

2

2

RX

TX

SET A

SET B

Operating manual

Cable Conductor Test Set CCTS-03

The CCTS-03 cable conductor testing device is used to check conductors 

for continuity, interchanging, interruption and earth fault. Due to micropro-

cessor-controlled technology, testing on active analogue and ISDN lines with 

or without xDSL is possible for the fi rst time. Simple and robust push-button 

control with LED display simplifi es operation in the fi eld. Automatic switch-off  

after approx. 100 min. prolongs battery life.

Start-up of the Cable Conductor Test Set

Connecting the devices

First, the headset is connected to CCTS-03 via the headset jack 

. CCTS-03 

is switched on by pressing the ON/OFF key >30 ms. The ON LED fl ashes 

rapidly. In this mode, the talk function is activated. A free pair of wires is 

connected to the black banana sockets as a voice pair via the black test 

leads, the polarity does not have to be observed. If earth fault testing is also 

required, the test lead for the TX unit must also be grounded.

At  the  far  end,  connect  the  second  CCTS-03  as  well  as  the  fi rst  device. 

Voice connection is now active.

The red test cord is plugged into the red socket. One device must be set as 

encoder (TX) and one device as evaluator (RX). This is done by pressing 

and holding the RX/TX key for more than 2 seconds. The LEDs RX and TX 

will be switched on and off  one after the other. To activate the desired mode, 

the key must be released according to the LED. The LED then starts fl ashing 

slowly to indicate the active mode. There is no need to make any further 

settings for the device in TX mode.

Testing on free / unconnected wires

The device in RX mode is automatically adjusted to the maximum possible 

line resistance after switching on the RX mode and can normally be used for 

testing (unswitched wires) immediately without any additional adjustment.

Testing on live / connected wires

Since the resistance diff erence between A- and B-wire is very small for con-

nected wire pairs, especially with ISDN-connected wires, it was impossible 

to diff erentiate between A and B so far. The CCTS-03 cable conductor tester 

therefore has the possibility to carry out a microprocessor-controlled adjust-

ment. To activate it, proceed as follows: The probes are connected with a 

reference wire on both sides. This can be a free or occupied wire. Because 

the CCTS-03 analyzes resistance diff erences smaller than <100 Ω, a good 

conenction must be ensured

After applying the test probes to the wire to be tested (test tone must be 

audible!), press the Auto Adjustment button on the instrument in RX mode 

>1 sec until the RX LED starts fl ashing rapidly. Release the button. The RX 

LED fl ashes rapidly during the entire adjustment process.

If the wire to be tested is not found or the calibration cannot be carried out for 

other reasons (cable resistance too low <20 Ω or too high >3 kΩ, test probe 

removed too early, or similar), a warning tone consisting of three short tones 

sounds in the handset. Then the adjustment may have to be repeated. If this 

is repeatedly negative, the connected twisted pairs must be separated at the 

MDF and, if necessary, at the DMARC.

Automatic adjustment for connected wires

After placing the probe on the wire to be tested, press the Auto Adjustment  

button in RX mode on the device >2 sec. The adjustment process starts after 

releasing the key. The RX LED fl ashes rapidly during adjustment. If the wire 

to be tested cannot be found, a warning tone consisting of three short tones 

sounds in the speaker. If it is the correct wire, the test tone sounds once for 

approx. 1 second, then stops for approx. 1 second and then comes as a 

constant tone. Only then is the device adjusted.

If the probe is removed, the test tone stops. If the test tone is not stable, 

i. e. arrives with interruptions (stuttering) or if other wires also receive the 

test tone without an error (e. g. switched ISDN lines), it can be fi ne-tuned 

by briefl y (<2 sec) pressing the 

+

 and 

-

 keys. Normally you only have to 

adjust in the direction minus (

-

) as CCTS-03 always adjusts a little more in 

the direction 

+

. This adjustment is usually only necessary in extreme cases. 

Manual readjustment

If the test tone does not arrive stable on the wire to be tested, i. e. with 

interruptions (stuttering), the evaluation is at the lower limit. Pressing the 

+

 button (<1 sec) once or twice briefl y shifts the evaluation threshold, thus 

stabilizing the tone.

If the test tone on the wire to be tested is evaluated in a stable manner and 

the test tone arrives with stuttering on adjacent wires, the evaluation is at 

the upper limit. By pressing the 

-

 button (<1 sec) once or twice, the eva-

luation threshold is moved downwards and the tone on the adjacent wire 

disappears.

After each manual adjustment, check again whether the tone on the wire 

to be tested is still stable. 

This adjustment is usually only necessary in 

border areas.

If, however, the test tone is permanently received (without interruption) on 

other wires despite readjustment, there may be a cable fault which must be 

checked for with the corresponding measuring instruments.

Testing the wires

Switch on both units as described and adjust if necessary. When the voice 

connection is established, 

A

 connects the red test cord 

 with the wire to be 

tested and notifi es 

B

 of this. If this wire has a touch to another wire or if it is 

interchanged, the sound becomes audible. If there is no sound, 

B

 places his 

probe 

 on the announced wire. If this is continuous, the sound becomes 

audible. 

B

 now informs 

A

 that his probe is „on“. 

A

 now changes its probe 

tip 

 to the next wire to be tested in the cable. No sound may be heard yet. 

He communicates the request of the probe tip again to 

B

, which now also 

applies the probe tip to the announced wire. In this way, a higher-pair cable 

can be checked quickly and easily.

Attention: The speech connection must be routed via a free pair of 

wires!

If the adjustment is successful, the green LED stops fl ashing quickly 

and the test tone is continuously audible. Only then is the device 

adjusted and the probes can be removed from the reference wire. 

Kurth Electronic GmbH | Muehleweg 11 | D 72800 Eningen u.A. GERMANY | Tel. +49(0)7121 9755 0

Fax +49(0)7121 9755 56 | [email protected] | www.kurthelectronic.de