Supports accept many types of rails. Job site scrap may be used.

Notes 
1. Installation by a licensed electrician only.  Make sure power is off. 
    Building wires must be in compliance with local codes. 
2. Rails are not supplied unless ordered. They come in two sizes 
    26" and 52". Contact the factory. Available immediately.  
3. Fixture must be above ceiling before closing in. 
 
Installation 
1. Fasten rail supports to internal adjustment brackets on housing. 
    Insert rails by gently squeezing wings of rail supports 
    together to ease passage of rails. Do not squeeze too hard or 
    the rail supports will take a set. When pressure is released, the 
    rail support will lock onto rails. (See Figs. 3 & 7) 
2. Remove proper knockouts from junction box and attach connectors. 
3. If alignment of square aperture is required, with trim removed, loosen 
    (2) wing nuts. Align aperture. Tighten wing nuts. (See Figs. 1 & 2) 
4. Using the aperture as a template, mark tile for the aperture hole. 
5. Cut hole in tile for a snug fit around the aperture. 
6. Adjust fixture so aperture is flush with finished tile face or 1/16" 
    above. Do not allow aperture edge below tile face or more than 
    1/16" above. Tighten rails to ceiling grid permanently. (See Fig. 7) 
 
Wiring  
1. Attach conduit or flex to junction box. Make all splices. 
2. Fixture must be grounded with green screw or grounding wire provided. 
 
Installation / Removal of LED Module Assembly 
(See Figs. 5 through 6a) 
1. Fixture yoke is pre-set in the wall wash position with locking screw. 
    Locking screw may be TEMPORARILY removed to provide additional 
    clearance for access to fixture's junction box or driver assembly. 
    Locking screw must be reinserted upon completion. 
2. Push in LED wire plug into two pin plug inside connector box. 
3. Coil wires inside connector box, line tabs up with holes  
    on heat sink. 
4. Secure the connector box to top of heat sink with two screws. 
5. Engage LED module bracket into yoke until springs engage into slots. 
6. Position Yoke so upper reflector is facing perpendicular to wall 
    Lock rotation disk in place with locking lever. 
7. To remove, depress spring. Pull module assembly gently from yoke. 
    DO NOT PUSH OR PULL upper reflector to remove module assembly. 
8. Loosen two screws at top of heatsink and slide connector box away 
    from heatsink to access LED wire plug. Disconnect from two pin driver 
    plug to completely free module assembly from fixture. 
 
Installation of Trim (See Figs. 2 & 4)  
1. Attach safety chain. 
2. Gently squeeze springs sides of trim and insert trim into aperture until 

flush with ceiling on all sides. Install trim as shown in Fig. 2. 

 

Access to Junction Box: (See Figs. 1 & 2)  
Remove trim (disconnect safety chain) and LED module inside yoke. 
Press up on spring clip remove inner junction box cover. 
 
Quality Control
 
Every effort is made to assure that our products reach the job 
in perfect condition. We welcome your comments. 
Kurt Versen Company may change construction periodically without 
notice as part of its program for product improvement. 
 

Fig. 3

RAIL SUPPORTS

RECESSED ROUND WALL WASH 
FIXTURES: 19mm XTM LED MODULES 
2800 Lumen Artist Series & Vibrant Series V95 models 
4000 Lumen & 5000 Lumen Standard Series models 

NOTE!! Before ceiling is closed, loosening of wing nuts 
provides the ability to adjust aperture frame, facilitating 
alignment with adjacent fixtures. Re-tighten wing nuts 
when desired alignment is attained. 

1/2" BAR

1/2" CONDUIT

1" BAR

1/2" - 1" ANGLE

1-1/2" CHANNEL

1"

CHANNEL

Thermal

Protector

Wing Nuts

Junction

Box

Power Supply Connector

Led Driver

Assembly

Connector Box

Inner Junction Box Cover

Upper reflector

Housing Top

Housing

Spring

Clip

Green

Grounding

Screw

approx. 1/4" both directions 

(left to right / forward and backward)

 

Aperture

Frame

Trim Assembly

WALL 

Kicker Reflector

Fig. 1

Fig. 2

Summary of Contents for XTM LED MODULES

Page 1: ...side connector box 3 Coil wires inside connector box line tabs up with holes on heat sink 4 Secure the connector box to top of heat sink with two screws 5 Engage LED module bracket into yoke until springs engage into slots 6 Position Yoke so upper reflector is facing perpendicular to wall Lock rotation disk in place with locking lever 7 To remove depress spring Pull module assembly gently from yok...

Page 2: ...downlight locking screw Fig 4 Fig 5 Fig 6 Fig 6a Connector Box attachment Fig 5b View into fixture from below ceiling line NOTE Wall Wash trim not shown for purposes of clarity WALL Incorrect upper reflector orientation Correct upper reflector orientation WALL ARROW MUST BE PERPENDICULAR TO WALL TO BE LIGHTED KV6963 93079817 REV B Connector Box Housing Screw Screw Wing nut Rail by others Internal ...

Page 3: ...de lèche mur avec une vis de blocage La vis de blocage peut être retirée TEMPORAIREMENT pour fournir un dégagement supplémentaire pour l accès à la boîte de jonction ou à l ensemble du pilote du luminaire La vis de blocage doit être réinsérée une fois l installation terminée 2 Enfoncer la fiche à fil de la DEL dans la fiche à deux broches dans le boîtier de raccordement 3 Bobiner les fils à l inté...

Page 4: ...de raccordement Fig 4 Fig 5 Fig 6 Fig 5b Vue dans le luminaire depuis la ligne du plafond REMARQUE La garniture du lèche mur n est pas illustrée à des fins de clarté MUR Orientation incorrecte du réflecteur supérieur Orientation correcte du réflecteur supérieur MUR LA FLÈCHE DOIT ÊTRE PERPENDICULAIRE AU MUR À ÉCLAIRER KV6963 93079817 REV B Boîte de raccordement Logement Vis Vis Écrou à oreilles Ra...

Reviews: