background image

18

EN

G

1

Ø150/ 120 mm reduction.

1

Anti-recoil valve.

1

Support for tubecover.

4

Wall plugs (Ø8 x 40).

4

Long bolts (Ø5 x 45).

2

Wall plugs (Ø6 x 30).

2

Long bolts (Ø4 x 30).

2

Washers (Ø6.4 x Ø18).

2

Screws (Ø3.9 x 13).

2

Clips.

Fig. 1 (Page 19)
On installing the kitchen hood make sure

that the Safety Instructions set out on page

14 are complied with.

To obtain optimum performance, the external

conduct must be no more than FOUR

METRES LONG, have no more than two 90°

angles and its diameter must be at least Ø120.
1) Trace and drill the points for fitting the wall

plugs onto the wall (A1) (Ø8 x 40). See figure

1.
2) Fit the wall plugs (A1) (Ø8 x 40) and screw

in the long bolts (A2) (Ø5 x 45) leaving them

protruding 5 mm out of the wall.
3) Attach the kitchen hood to the long bolts

(A2) (Ø5 x 45). Straighten the appliance and

tighten the long bolts.
4) Trace the location of the wall plugs (R) (Ø8

x 40), through the inside of the kitchen hood.
5) Loosen the long bolts (A2) (Ø5 x 45) and

take the kitchen hood off.
6) Drill into the wall and fit the wall plugs (R)

(Ø8 x 40).
7) Attach the kitchen hood, tighten the long

bolts (A2) (Ø5 x 45) and (S) (Ø5 x 45) with the

washers (T) (Ø6.4 x Ø18).
8) Mount the tubecovers. Lift the upper

tubecover up to the desired height and mark its

shape on the wall. Remove the tubecovers.
9) Fit the clips (F) to the support (C).
10) Center the support (C) around the shape

marked; trace and drill the fixing points for the

wall plugs (E) (Ø6 x 30). Attach the support (C)

with the long bolts (D) (Ø4 x 30).
11) Fit the part (A) if the inner tube (not

supplied) is Ø150 or (A) + (B) if it is Ø120.
12) Attach the inner tube with a clamp (not

supplied) to (A) or (B) as the case may be.
13) Once the inner tube is fitted, fit the lower

tubecover around the extractor fan outlet and

attach the uppe

When exterior gas extraction is not possible,

then the kitchen hood may be set to purify the

air by recycling it through active charcoal

filters.
The active charcoal filters have an active life of

between three to six months, depending on

the individual conditions of use. These filters

cannot be washed nor regenerated. They must

be replaced once their useful life comes to an

end.

Fig. 2 (Page 19)

1) Put the filters into the lateral draught section

of the motor making the holes in the filters

match up (A) with the pivots (B) of the motor

carcass. Turn as indicated in the diagram.
2) Remove the tubecovers (E). Fit the diffuser

(C) on to the motor's air outlet vent. Fit the

tubecovers back on (E).

Installation

Active charcoal filters (Optional)

Accesories supplied

Summary of Contents for KD 9200.2 E

Page 1: ...use and installation Instructions d utilisation e avis de montage Instruηυes de uso com indicaηυes para montagem Istruzioni di uso e di montaggio Bruks och monteringsanvisningar Gebruiksaanwijzing en montagehandleiding Εγχειριδίου µε τις Οδηγίεσ Χρήσεωσ KD 9200 2 E 702 7 KD 6200 2 E 702 7 Rev 0 ...

Page 2: ...itchen hood must be fitted at least 50 cm over electric hobs and 65 cm over gas or mixed hobs FOLLOW THE MANUFACTURER S MINIMUM RECOMMENDATIONS Never leave gas hobs lit if not covered by a container The fat accumulated in the filters may drip or catch fire when the temperature increases Avoid cooking under the kitchen hood if the metal filters are not fitted e g while they are being cleaned in the...

Page 3: ... W E 14 D E Vertically adjustable tubecovers Switch on the extractor fan a few minutes before you start to cook in order to ensure that a steady air flow has been established before fumes appear Allow the extractor fan to run for several minutes after you have finished cooking between 3 to 5 minutes in order to expel all the grease from the outlet duct This prevents the return of grease smoke and ...

Page 4: ...t dissolves and then rinsing them under the tap or using special anti grease products They can also be washed in a dishwasher In this case it is advisable to stack them vertically to avoid food residues to stick to them Cleaning in a dishwasher may damage the metallic surface blackening it although this will not affect its fat retention capacity Once clean leave them to dry off and then fit them o...

Page 5: ...265 235 MIN MAX 800 ELEC AC 220 240V 50 60Hz M W Código Técnico F Nr F PTX KÜPPERSBUSCH reserves the right to make changes and corrections to its products as it deems necessary without altering their basic characteristics Check Characteristics label inside the hood ...

Page 6: ... the tubecovers Lift the upper tubecover up to the desired height and mark its shape on the wall Remove the tubecovers 9 Fit the clips F to the support C 10 Center the support C around the shape marked trace and drill the fixing points for the wall plugs E Ø6 x 30 Attach the support C with the long bolts D Ø4 x 30 11 Fit the part A if the inner tube not supplied is Ø150 or A B if it is Ø120 12 Att...

Page 7: ...19 ENG 273 165 MIN 500 MIN 650 FIG 1 FIG 2 ...